High temperature strain measurements using digital optics. Final report, September 1989-September 1991
Abstract
Current methods used to measure strain at high temperatures depend on undesireable attachments or indentations and are generally limited to temperatures below 1800 deg F. The objective of this effort is to develop, construct, and demonstrate an ultrahigh-temperature strain measurement system using unobtrusive thin material coatings applied to test samples as reference marks for optical strain monitoring. The contents of this report describe the development of a system capable of measuring strain on specimens at temperatures ranging from room temperature to above 2000 deg F.... High temperatures, Strain measurements, High-temperature coatings, Optical methods, Gage marks, Sputtering methods.
- Authors:
- Publication Date:
- Research Org.:
- Terra Tek, Inc., Salt Lake City, UT (United States)
- OSTI Identifier:
- 6251812
- Report Number(s):
- AD-A-266331/8/XAB; TTI-TR-92-21
CNN: F33615-89-C-3216
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 36 MATERIALS SCIENCE; 42 ENGINEERING; 47 OTHER INSTRUMENTATION; COATINGS; THERMAL STRESSES; OPTICAL SYSTEMS; DESIGN; STRAIN GAGES; DIGITAL SYSTEMS; OPTICAL PROPERTIES; PERFORMANCE TESTING; STRAIN RATE; TEMPERATURE DEPENDENCE; TEMPERATURE RANGE 0400-1000 K; TRANSDUCERS; MEASURING INSTRUMENTS; PHYSICAL PROPERTIES; STRESSES; TEMPERATURE RANGE; TESTING; 360603* - Materials- Properties; 420500 - Engineering- Materials Testing; 440600 - Optical Instrumentation- (1990-)
Citation Formats
Nielsen, R R. High temperature strain measurements using digital optics. Final report, September 1989-September 1991. United States: N. p., 1991.
Web.
Nielsen, R R. High temperature strain measurements using digital optics. Final report, September 1989-September 1991. United States.
Nielsen, R R. Sun .
"High temperature strain measurements using digital optics. Final report, September 1989-September 1991". United States.
@article{osti_6251812,
title = {High temperature strain measurements using digital optics. Final report, September 1989-September 1991},
author = {Nielsen, R R},
abstractNote = {Current methods used to measure strain at high temperatures depend on undesireable attachments or indentations and are generally limited to temperatures below 1800 deg F. The objective of this effort is to develop, construct, and demonstrate an ultrahigh-temperature strain measurement system using unobtrusive thin material coatings applied to test samples as reference marks for optical strain monitoring. The contents of this report describe the development of a system capable of measuring strain on specimens at temperatures ranging from room temperature to above 2000 deg F.... High temperatures, Strain measurements, High-temperature coatings, Optical methods, Gage marks, Sputtering methods.},
doi = {},
url = {https://www.osti.gov/biblio/6251812},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1991},
month = {9}
}
Other availability