Title: Front-end module readout and control electronics for the PHENIX multiplicity vertex detector

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.682646· OSTI ID:624226
 [1];  [2];  [3]
  1. Oak Ridge National Lab., TN (United States)
  2. Univ. of Tennessee, Knoxville, TN (United States)
  3. Los Alamos National Lab., NM (United States)

Front-end module (FEM) readout and control are implemented as modular, high-density, reprogrammable functions in the PHENIX Multiplicity Vertex Detector. FEM control is performed by the heap manager, an FPGA-based circuit in the FEM unit. Each FEM has 256 channels of front-end electronics, readout, and control, all located on an MCM. Data readout, formatting, and control are performed by the heap manager along with 4 interface units that reside outside the MVD detector cylinder. This paper discusses the application of a generic heap manager and the addition of 4 interface module types to meet the specific control and data readout needs of the MVD. Unit functioning, interfaces, timing, data format, and communication rates will be discussed in detail. In addition, subsystem issues regarding mode control, serial architecture and functions, error handling, and FPGA implementation and programming is presented.

Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-96OR22464
OSTI ID:
624226
Report Number(s):
CONF-971147-; ISSN 0018-9499; TRN: 98:006479
Journal Information:
IEEE Transactions on Nuclear Science, Vol. 45, Issue 3Pt1; Conference: Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference, Albuquerque, NM (United States), 11-13 Nov 1997; Other Information: PBD: Jun 1998
Country of Publication:
United States
Language:
English