Title: A test method for the measurement of arylamines in stationary source emissions

Abstract

Title III of the Clean Air Act Amendments of 1990 lists eighteen arylamines as hazardous air pollutants to be regulated. The eighteen arylamines range from semivolatile to almost nonvolatile, from almost water-insoluble to hygroscopic, from thermally quite stable to unstable, and from fairly toxic to confirmed human carcinogens. This paper presents a report on progress in the development of a method to measure this quite disparate group of compounds in stationary source emissions. The proposed method involves collection in an acidic aqueous solution, sorption of collected arylamines on a cation exchange resin, desorption of arylamines from the resin with a small volume of a basic solution, and separation and measurement by high pressure liquid chromatography with photodiode array (HPLC-PDA) detection. Evaluation of cation exchange resins and resin elution solvents and the analytical portions of the method are being conducted using a subset of eight arylamines: aniline, chloramben, 2,4-diaminotoluene, N,N-dimethylaniline, 3,3`-dimethylbenzidine, quinoline, o-toluidine, and trifluralin. Sorption on a solid-phase extraction resin (LC-SCX, Supelco) followed by elution off the resin with a 2.2 normal solution of ammonia in a 50:35:15 mixture of 1-butanol, 1-propanol, and water gave the best recoveries of the test compounds (except chloramben, which contains a carboxylic acid groupmore » and does not elute) from the acidified collection solution. The compounds were separated on an Alltech Alltima C18 5{mu}m, 150 {times} 4.6 mm HPLC column using solvent programming with acetonitrile and either water or an acetate/acetic acid pH 7 buffer. 1 fig., 3 tabs.« less

Authors:
; ;  [1]
  1. Research Triangle Institute, Research Triangle Park, NC (United States) [and others
Publication Date:
OSTI Identifier:
617663
Report Number(s):
CONF-9605175-
TRN: 98:002112-0045
Resource Type:
Conference
Resource Relation:
Conference: International symposium on measurement of toxic and related air pollutants, Research Triangle Park, NC (United States), 7-10 May 1996; Other Information: PBD: 1996; Related Information: Is Part Of Measurement of toxic and related air pollutants; PB: 889 p.
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; AMINES; AROMATICS; AIR POLLUTION MONITORING; STATIONARY POLLUTANT SOURCES; ION EXCHANGE MATERIALS; SOLVENTS; PERFORMANCE TESTING; EFFICIENCY

Citation Formats

Peterson, M.R., Pate, B.A., and Wright, R.S. A test method for the measurement of arylamines in stationary source emissions. United States: N. p., 1996. Web.
Peterson, M.R., Pate, B.A., & Wright, R.S. A test method for the measurement of arylamines in stationary source emissions. United States.
Peterson, M.R., Pate, B.A., and Wright, R.S. Tue . "A test method for the measurement of arylamines in stationary source emissions". United States.
@article{osti_617663,
title = {A test method for the measurement of arylamines in stationary source emissions},
author = {Peterson, M.R. and Pate, B.A. and Wright, R.S.},
abstractNote = {Title III of the Clean Air Act Amendments of 1990 lists eighteen arylamines as hazardous air pollutants to be regulated. The eighteen arylamines range from semivolatile to almost nonvolatile, from almost water-insoluble to hygroscopic, from thermally quite stable to unstable, and from fairly toxic to confirmed human carcinogens. This paper presents a report on progress in the development of a method to measure this quite disparate group of compounds in stationary source emissions. The proposed method involves collection in an acidic aqueous solution, sorption of collected arylamines on a cation exchange resin, desorption of arylamines from the resin with a small volume of a basic solution, and separation and measurement by high pressure liquid chromatography with photodiode array (HPLC-PDA) detection. Evaluation of cation exchange resins and resin elution solvents and the analytical portions of the method are being conducted using a subset of eight arylamines: aniline, chloramben, 2,4-diaminotoluene, N,N-dimethylaniline, 3,3`-dimethylbenzidine, quinoline, o-toluidine, and trifluralin. Sorption on a solid-phase extraction resin (LC-SCX, Supelco) followed by elution off the resin with a 2.2 normal solution of ammonia in a 50:35:15 mixture of 1-butanol, 1-propanol, and water gave the best recoveries of the test compounds (except chloramben, which contains a carboxylic acid group and does not elute) from the acidified collection solution. The compounds were separated on an Alltech Alltima C18 5{mu}m, 150 {times} 4.6 mm HPLC column using solvent programming with acetonitrile and either water or an acetate/acetic acid pH 7 buffer. 1 fig., 3 tabs.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1996},
month = {12}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: