Title: 1000 hour test programme in a pressurised fluidised bed combustion facility. Volume III. Combustor emissions and hot gas clean-up. Final report

Abstract

This appendix to a report on the operation and performance of pressurized fluidized bed combustors and cyclone separator hot gas clean-up systems for combined-cycle power plants presents the procedures used and results obtained. The following studies are described: characterization of particles in combustor emissions and in hot gas cleanup system emissions; effects of electrical charges on combustion emission particles collection; alkali and SO/sub 3/ monitoring of combustor emissions; methods for measuring combustor emission particle quantities and size before and after hot gas cleanup. (LCL)

Research Org.:
National Coal Board, Leatherhead (UK). Coal Utilization Research Lab.
OSTI Identifier:
6097505
Report Number(s):
DOE/ET/10423-1103
ON: DE81030970
DOE Contract Number:  
AC01-78ET10423
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
20 FOSSIL-FUELED POWER PLANTS; COMBINED-CYCLE POWER PLANTS; FLUIDIZED-BED COMBUSTORS; CYCLONE SEPARATORS; PERFORMANCE; HOT GAS CLEANUP; AIR POLLUTION CONTROL; COAL; ELECTRIC CHARGES; EXPERIMENTAL DATA; FLUIDIZED-BED COMBUSTION; FOSSIL-FUEL POWER PLANTS; PARTICLE SIZE; PARTICLES; PERFORMANCE TESTING; CARBONACEOUS MATERIALS; CHEMICAL REACTIONS; COMBUSTION; COMBUSTORS; CONCENTRATORS; CONTROL; DATA; ENERGY SOURCES; EQUIPMENT; FOSSIL FUELS; FUELS; INERTIAL SEPARATORS; INFORMATION; MATERIALS; NUMERICAL DATA; OXIDATION; POLLUTION CONTROL; POLLUTION CONTROL EQUIPMENT; POWER PLANTS; PURIFICATION; SEPARATION EQUIPMENT; SIZE; TESTING; THERMAL POWER PLANTS; THERMOCHEMICAL PROCESSES; 200104* - Fossil-Fueled Power Plants- Components; 200102 - Fossil-Fueled Power Plants- Power Cycles; 200202 - Fossil-Fueled Power Plants- Waste Management- Noxious Gas & Particulate Emissions

Citation Formats

Not Available. 1000 hour test programme in a pressurised fluidised bed combustion facility. Volume III. Combustor emissions and hot gas clean-up. Final report. United States: N. p., Web.
Not Available. 1000 hour test programme in a pressurised fluidised bed combustion facility. Volume III. Combustor emissions and hot gas clean-up. Final report. United States.
Not Available. . "1000 hour test programme in a pressurised fluidised bed combustion facility. Volume III. Combustor emissions and hot gas clean-up. Final report". United States.
@article{osti_6097505,
title = {1000 hour test programme in a pressurised fluidised bed combustion facility. Volume III. Combustor emissions and hot gas clean-up. Final report},
author = {Not Available},
abstractNote = {This appendix to a report on the operation and performance of pressurized fluidized bed combustors and cyclone separator hot gas clean-up systems for combined-cycle power plants presents the procedures used and results obtained. The following studies are described: characterization of particles in combustor emissions and in hot gas cleanup system emissions; effects of electrical charges on combustion emission particles collection; alkali and SO/sub 3/ monitoring of combustor emissions; methods for measuring combustor emission particle quantities and size before and after hot gas cleanup. (LCL)},
doi = {},
journal = {},