Technical evaluation of the adequacy of station electric-distribution-system voltages for the St. Lucie Nuclear Power Plant, Unit 1
Technical Report
·
OSTI ID:6096821
This report documents the technical evaluation of the adequacy of the station electric distribution system voltages for the St. Lucie Nuclear Power Plant, Unit 1. The evaluation is to determine if the onsite distribution system, in conjunction with the offsite power sources, has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. The voltage analysis submitted has adequately demonstrated the capacity and capability of the electrical distribution system to supply adequate voltage to the Class 1E equipment under worst case operating conditions.
- Research Organization:
- Lawrence Livermore National Lab., CA (USA)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 6096821
- Report Number(s):
- UCID-19110; ON: DE82003923
- Country of Publication:
- United States
- Language:
- English
Similar Records
Technical evaluation of the adequacy of station electric-distribution-system voltages for the Duane Arnold Energy Center
Technical-evaluation report on the adequacy of station electric-distribution-system voltages for the Vermont Yankee Nuclear Power Station. Document No. 50-271
Technical-evaluation report on the adequacy of station electric-distribution-system voltages for the Prairie Island Nuclear Generating Plant, Units 1 and 2. (Docket Nos. 50-282, 50-306)
Technical Report
·
Mon Oct 12 00:00:00 EDT 1981
·
OSTI ID:6096821
Technical-evaluation report on the adequacy of station electric-distribution-system voltages for the Vermont Yankee Nuclear Power Station. Document No. 50-271
Technical Report
·
Fri Sep 03 00:00:00 EDT 1982
·
OSTI ID:6096821
Technical-evaluation report on the adequacy of station electric-distribution-system voltages for the Prairie Island Nuclear Generating Plant, Units 1 and 2. (Docket Nos. 50-282, 50-306)
Technical Report
·
Fri Sep 17 00:00:00 EDT 1982
·
OSTI ID:6096821
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
LUCIE-1 REACTOR
ELECTRICAL EQUIPMENT
POWER SUPPLIES
PERFORMANCE
QUALITY ASSURANCE
ELECTRONIC EQUIPMENT
ENRICHED URANIUM REACTORS
EQUIPMENT
POWER REACTORS
PWR TYPE REACTORS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
LUCIE-1 REACTOR
ELECTRICAL EQUIPMENT
POWER SUPPLIES
PERFORMANCE
QUALITY ASSURANCE
ELECTRONIC EQUIPMENT
ENRICHED URANIUM REACTORS
EQUIPMENT
POWER REACTORS
PWR TYPE REACTORS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled