skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Time-resolving electron temperature diagnostic for ALCATOR C

Technical Report ·
OSTI ID:6085554

A diagnostic that provides time-resolved central electron temperatures has been designed, built, and tested on the ALCATOR C Tokamak. The diagnostic uses an array of fixed-wavelength x-ray crystal monochromators to sample the x-ray continuum and determine the absolute electron temperature. The resolution and central energy of each channel were chosen to exclude any contributions from impurity line radiation. This document describes the need for such a diagnostic, the design methodology, and the results with typical ALCATOR C plasmas. Sawtooth (m = 1) temperature oscillations were observed after pellet fueling of the plasma. This is the first time that such oscillations have been observed with an x-ray temperature diagnostic.

Research Organization:
Massachusetts Inst. of Tech., Cambridge (USA). Plasma Fusion Center
DOE Contract Number:
AC02-78ET51013
OSTI ID:
6085554
Report Number(s):
DOE/ET/51013-124; PFC/RR-84-8; ON: DE85004916; TRN: 85-005949
Resource Relation:
Other Information: Portions are illegible in microfiche products. Thesis
Country of Publication:
United States
Language:
English