skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Indoor /sup 222/Rn measurements in the region of Beijing, People's Republic of China

Journal Article · · Health Phys.; (United States)
OSTI ID:6078929

Passive integrating activated C detectors were used to study the regional distribution and temporal variation of /sup 222/Rn in indoor air in dwellings in the Beijing region. Measurements were made in 537 dwellings, which were either detached houses or multi-family apartments. The city-wide study was completed in 1985. The distributions are approximately log-normal with 90% of the dwellings having /sup 222/Rn levels less than 60 Bq m-3. The weighted average /sup 222/Rn concentration has been found to be 22.4 Bq m-3. Averages for detached houses and multi-family dwellings are 25.9 and 15.2 Bq m-3, respectively. Assuming an equilibrium factor of 0.5 and an occupancy factor of 0.8, the average equilibrium equivalent concentration of /sup 222/Rn progeny is 11.2 Bq m-3 and the annual average effective dose equivalent is 1.1 mSv.

Research Organization:
Laboratory of Industrial Hygiene, MPH, Deshengmenwai, Beijing, People's Republic of China
OSTI ID:
6078929
Journal Information:
Health Phys.; (United States), Vol. 53:3
Country of Publication:
United States
Language:
English