skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Tennessee Valley Authority/Consumer Product Safety Commission. Indoor air quality study. Volume I

Technical Report ·
OSTI ID:6059923

The study addressed the concern over indoor air quality as affected by the use of a non-airtight wood heaters in a relatively tight, unoccupied home. The results of this study, along with earlier testing by TVA and others, associated with wood heater emissions, will serve as a data base for considering the effect of wood heaters on indoor air quality. The test program was performed using a well insulated, single story modular home with a low air exchange rate as the test home (the same home as was used in the 1983 study). Three different types of non-airtight wood heaters were tested during the study, which was conducted during the winter months of calender year 1984. 44 refs., 93 figs., 40 tabs.

Research Organization:
Tennessee Valley Authority, Chattanooga (USA). Energy Use Test Facility Staff
OSTI ID:
6059923
Report Number(s):
TVA/PE/CEM-85/84; ON: DE86900920
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English