skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The System 80+ Standard Plant design control document. Volume 17

Abstract

This Design Control Document (DCD) is a repository of information comprising the System 80+{trademark} Standard Plant Design. The DCD also provides that design-related information to be incorporated by reference in the design certification rule for the System 80+ Standard Plant Design. Applicants for a combined license pursuant to 10 CFR 52 must ensure that the final Design Certification Rule and the associated Statements of Consideration are used when making all licensing decisions relevant to the System 80+ Standard Plant Design. The Design Control Document contains the DCD introduction, The Certified Design Material (CDM) [i.e., ``Tier 1``] and the Approved Design Material (ADM) [i.e., ``Tier 2``] for the System 80+ Standard Plant Design. The CDM includes the following sections: (1) Introductory material; (2) Certified Design Material for System 80+ systems and structures; (3) Certified Design Material for non-system-based aspects of the System 80+ Certified design; (4) Interface requirements; and (5) Site parameters. The ADM, to the extent applicable for the System 80+ Standard Plant Design, includes: (1) the information required for the final safety analysis report under 20 CFR 50.34; (2) other relevant information required by 10 CFR 52.47; and (3) emergency operations guidelines. This volume contains parts 2-7 and appendixmore » 15A for section 15 (Accident Analysis) of the ADM Design and Analysis. Topics covered in these parts are: decrease in heat removal; decrease in RCS flow rate; power distribution anomalies; increase in RCS inventory; decrease in RCS inventory; release of radioactive materials. The appendix covers radiological release models. Also contained here are five technical specifications for section 16 (Technical Specifications) of the ADM Design and Analysis. They are: TS 1.0 Use and Applications; TS 2.0 Safety Limits; TS 3.0 LCO Availability; TS 3.1 Reactivity Control; and TS 3.2 Power Distribution.« less

Publication Date:
Research Org.:
ABB Combustion Engineering, Inc., Windsor, CT (United States)
Sponsoring Org.:
USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States)
OSTI Identifier:
591336
Report Number(s):
DOE/SF/19090-T4-Vol.17
TRN: 98:004630
DOE Contract Number:
AC03-91SF19090
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: [1997]
Country of Publication:
United States
Language:
English
Subject:
21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS; 22 NUCLEAR REACTOR TECHNOLOGY; CE STANDARD REACTOR; REACTOR ACCIDENTS; REACTOR COOLING SYSTEMS; MATHEMATICAL MODELS; RADIATION DOSES; ENVIRONMENTAL IMPACTS; SPECIFICATIONS

Citation Formats

NONE. The System 80+ Standard Plant design control document. Volume 17. United States: N. p., 1997. Web.
NONE. The System 80+ Standard Plant design control document. Volume 17. United States.
NONE. Wed . "The System 80+ Standard Plant design control document. Volume 17". United States. doi:.
@article{osti_591336,
title = {The System 80+ Standard Plant design control document. Volume 17},
author = {NONE},
abstractNote = {This Design Control Document (DCD) is a repository of information comprising the System 80+{trademark} Standard Plant Design. The DCD also provides that design-related information to be incorporated by reference in the design certification rule for the System 80+ Standard Plant Design. Applicants for a combined license pursuant to 10 CFR 52 must ensure that the final Design Certification Rule and the associated Statements of Consideration are used when making all licensing decisions relevant to the System 80+ Standard Plant Design. The Design Control Document contains the DCD introduction, The Certified Design Material (CDM) [i.e., ``Tier 1``] and the Approved Design Material (ADM) [i.e., ``Tier 2``] for the System 80+ Standard Plant Design. The CDM includes the following sections: (1) Introductory material; (2) Certified Design Material for System 80+ systems and structures; (3) Certified Design Material for non-system-based aspects of the System 80+ Certified design; (4) Interface requirements; and (5) Site parameters. The ADM, to the extent applicable for the System 80+ Standard Plant Design, includes: (1) the information required for the final safety analysis report under 20 CFR 50.34; (2) other relevant information required by 10 CFR 52.47; and (3) emergency operations guidelines. This volume contains parts 2-7 and appendix 15A for section 15 (Accident Analysis) of the ADM Design and Analysis. Topics covered in these parts are: decrease in heat removal; decrease in RCS flow rate; power distribution anomalies; increase in RCS inventory; decrease in RCS inventory; release of radioactive materials. The appendix covers radiological release models. Also contained here are five technical specifications for section 16 (Technical Specifications) of the ADM Design and Analysis. They are: TS 1.0 Use and Applications; TS 2.0 Safety Limits; TS 3.0 LCO Availability; TS 3.1 Reactivity Control; and TS 3.2 Power Distribution.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Dec 31 00:00:00 EST 1997},
month = {Wed Dec 31 00:00:00 EST 1997}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share: