Title: Health Hazard Evaluation Report HETA 84-340-1606, Denver Laundry and Dry Cleaning, Denver, Colorado

Abstract

Environmental and breathing zone samples were analyzed for tetrachloroethylene (perchloroethylene) (PCE) at Denver Laundry and Dry Cleaning, Denver, Colorado in July, 1984. The evaluation was requested by a company representative to determine if a health hazard from exposure to PCE existed during the commercial laundry and dry cleaning processes. A noise evaluation was also requested. The author concludes that a health hazard exists due to overexposure to PCE and noise at the facility. Recommendations include replacing the present transfer system by a dry/to/dry closed system if possible, improving work practices, removing clothing from each machine at the same time replacing or cleaning and oiling the bearings in the dryers, and establishing an educational program to instruct new employees on the hazards of chemical and noise exposure.

Authors:
Publication Date:
Research Org.:
National Inst. for Occupational Safety and Health, Cincinnati, OH (USA)
OSTI Identifier:
5885168
Alternate Identifier(s):
OSTI ID: 5885168
Report Number(s):
PB-86-145349/XAB; HETA-84-340-1606
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; 99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE; HAZARDOUS MATERIALS; INDOOR AIR POLLUTION; LAUNDRIES; NOISE POLLUTION; OCCUPATIONAL SAFETY; INDUSTRIAL MEDICINE; INSPECTION; TOXICITY; VENTILATION; AIR POLLUTION; MATERIALS; MEDICINE; POLLUTION; SAFETY 500200* -- Environment, Atmospheric-- Chemicals Monitoring & Transport-- (-1989); 552000 -- Public Health

Citation Formats

Pryor, P. Health Hazard Evaluation Report HETA 84-340-1606, Denver Laundry and Dry Cleaning, Denver, Colorado. United States: N. p., 1985. Web.
Pryor, P. Health Hazard Evaluation Report HETA 84-340-1606, Denver Laundry and Dry Cleaning, Denver, Colorado. United States.
Pryor, P. Mon . "Health Hazard Evaluation Report HETA 84-340-1606, Denver Laundry and Dry Cleaning, Denver, Colorado". United States. doi:.
@article{osti_5885168,
title = {Health Hazard Evaluation Report HETA 84-340-1606, Denver Laundry and Dry Cleaning, Denver, Colorado},
author = {Pryor, P.},
abstractNote = {Environmental and breathing zone samples were analyzed for tetrachloroethylene (perchloroethylene) (PCE) at Denver Laundry and Dry Cleaning, Denver, Colorado in July, 1984. The evaluation was requested by a company representative to determine if a health hazard from exposure to PCE existed during the commercial laundry and dry cleaning processes. A noise evaluation was also requested. The author concludes that a health hazard exists due to overexposure to PCE and noise at the facility. Recommendations include replacing the present transfer system by a dry/to/dry closed system if possible, improving work practices, removing clothing from each machine at the same time replacing or cleaning and oiling the bearings in the dryers, and establishing an educational program to instruct new employees on the hazards of chemical and noise exposure.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jul 01 00:00:00 EDT 1985},
month = {Mon Jul 01 00:00:00 EDT 1985}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share:
  • Environmental surveys conducted on February 4 and July 16, 1985 at the Denver Water Department, Denver, Colorado, included collection of breathing-zone and general-area samples for asbestos and personal sampling for noise exposure. The Denver Water Department had requested an evaluation of potential health hazards to employees during cutting of cement pipes thought to contain asbestos.
  • In November 1983, the National Institute for Occupational Safety and Health (NIOSH) received a request to evaluate a potential health hazard to asbestos during the manufacture of asphalt-based protective coatings made from asphalt and asbestos at Grundy Industries, Inc., Denver, Colorado. On April 5, 1984 all employees were monitored for exposure to airborne asbestos. On the basis of data collected in this survey, the authors concluded that a health hazard from exposure to asbestos existed at Grundy Industries. Recommendations may be found in Section VIII of this report.
  • In response to a request from management at the NuTech Chemical Corporation located in Denver, Colorado, an evaluation was made of possible employee exposure to copper sulfate, sulfuric acid, and acetic acid at the facility. The company has recently begun producing odorizing chemicals for sulfuric acid waste treatment, food and by-products operations, set odors, and other uses. Personal breathing-zone and area samples for acetic acid ranged from 12.6 to 51.3 mg/cu m, indicating that some exceeded the OSHA Standard of 25 mg/cu m. Before the employees began using personal protective clothing, they had experienced irritation to the eyes, nose andmore » throat. Sulfuric acid and copper sulfate were not detected. The author recommends that a local exhaust ventilation system be installed in the chemical mixing location. An eyewash station and safety shower should be made immediately accessible to workers. Preplacement and periodic medical examinations should be instituted giving particular attention to skin, eyes, teeth, and respiratory-tract problems and including pulmonary function tests.« less
  • Environmental and breathing-zone samples were analyzed for acrylamide, butyl-acetate, acetic-acid, and hydrogen-sulfide at Big Dry Creek waste water treatment facility, Westminister, Colorado in July and November, 1984. Noise monitoring was also conducted. The survey was requested by a facility representative to evaluate potential health hazards associated with chemicals used in the waste-water-treatment process and from noise. The author concludes that a health hazard from chemical over exposure at the facility does not exist. A potential hazard does exist from noise over exposure. Evaluation of all air compressors, periodic noise monitoring, use of hearing protective devices using EPA noise reduction ratings,more » and an employee education program about chemical and noise exposure hazards are recommended.« less
  • A study of possible hospital employee exposure to ethylene oxide was undertaken. Employees had complained of headaches and possible neurological problems. A personal breathing-zone sample collected from the sterilizer operator showed levels of ethylene oxide at the limit of quantitation, 0.02mg/cu m. In sterilizer and mechanical-access-room samples, ethylene oxide was detected ranging up to 0.2mg/cu m levels. The authors conclude that a potential for exposure to ethylene oxide exists for workers in the sterilizer room. The authors recommend that efforts be continued to keep ethylene oxide levels as low as possible and to check for possible leaks in the system.more » Effective ventilation controls should be established, and a warning system should be installed in the mechanical access room. Respirators, protective clothing, training for employees, safety meetings, and medical evaluations for personnel were all included in the recommendations following the investigation.« less