Title: MFTFB+T magnetostatic and circuit fault-induced forces

Abstract

This report presents the results of work performed on the estimation of the Lorentz forces acting on the various coils in the MFTFB+T mirror machine. The analyses incude: (1) static loading under normal operating conditions; (2) transient loading during a normal discharge; and (3) transient loading for one coil short circuits with all coils discharging. For the purpose of this memo, normal operation is defined as any possible combination of circuits fully charged to their operating current level or at zero current. This definition would then include any possible scenario for the entire system or partial system at full operating current.

Authors:
; ; ;
Publication Date:
Research Org.:
Massachusetts Inst. of Tech., Cambridge (USA). Plasma Fusion Center
OSTI Identifier:
5860679
Report Number(s):
DOE/ET/51013-92; PFC/RR-83-21
ON: DE83016979
DOE Contract Number:  
AC02-78ET51013
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; MAGNET COILS; LORENTZ FORCE; MFTF DEVICES; ELECTRONIC CIRCUITS; FAILURES; MATHEMATICAL MODELS; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; THERMONUCLEAR DEVICES; 700202* - Fusion Power Plant Technology- Magnet Coils & Fields

Citation Formats

Pillsbury, Jr., R. D., Thome, R. J., Mann, W. R., and Langton, W. G.. MFTFB+T magnetostatic and circuit fault-induced forces. United States: N. p., 1983. Web. doi:10.2172/5860679.
Pillsbury, Jr., R. D., Thome, R. J., Mann, W. R., & Langton, W. G.. MFTFB+T magnetostatic and circuit fault-induced forces. United States. doi:10.2172/5860679.
Pillsbury, Jr., R. D., Thome, R. J., Mann, W. R., and Langton, W. G.. Mon . "MFTFB+T magnetostatic and circuit fault-induced forces". United States. doi:10.2172/5860679. https://www.osti.gov/servlets/purl/5860679.
@article{osti_5860679,
title = {MFTFB+T magnetostatic and circuit fault-induced forces},
author = {Pillsbury, Jr., R. D. and Thome, R. J. and Mann, W. R. and Langton, W. G.},
abstractNote = {This report presents the results of work performed on the estimation of the Lorentz forces acting on the various coils in the MFTFB+T mirror machine. The analyses incude: (1) static loading under normal operating conditions; (2) transient loading during a normal discharge; and (3) transient loading for one coil short circuits with all coils discharging. For the purpose of this memo, normal operation is defined as any possible combination of circuits fully charged to their operating current level or at zero current. This definition would then include any possible scenario for the entire system or partial system at full operating current.},
doi = {10.2172/5860679},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Aug 01 00:00:00 EDT 1983},
month = {Mon Aug 01 00:00:00 EDT 1983}
}