Development and demonstration of a Stirling/Rankine heat activated heat pump. Volume II. Phase II program test data. Final report
Technical Report
·
OSTI ID:5827410
This report presents the results of the Phase II and Phase IIIB Stirling/Rankine Heat Activated Heat Pump produce development program. In the Phase II program, a complete gas fired heat activated prototype residential heat pump system was developed and tested. Detailed test data from the Phase II program are presented in Volume II of this report. Results of the Phase II program indicated deficiencies in the performance of the free-piston Stirling engine and mismatching of the dynamic characteristics of the engine and the compressor.
- Research Organization:
- General Electric Co., Philadelphia, PA (USA). Advanced Energy Programs Dept.
- DOE Contract Number:
- AC02-77CS20043; AC05-84OR21400
- OSTI ID:
- 5827410
- Report Number(s):
- DOE/CS/20043-T7; ON: DE86010125
- Resource Relation:
- Other Information: Paper copy only, copy does not permit microfiche production
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development and demonstration of a Stirling/Rankine heat activated heat pump. Phase IIIB. Engine technology development testing. Final report
Development and demonstration of a Stirling/Rankine heat activated heat pump. Volume 1. Phase 2. Product development program. Final report
Development and demonstration of a Stirling/Rankine Heat Activated Heat Pump. Phase IIIB. Engine technology development testing. Final report
Technical Report
·
Mon Apr 09 00:00:00 EST 1984
·
OSTI ID:5827410
Development and demonstration of a Stirling/Rankine heat activated heat pump. Volume 1. Phase 2. Product development program. Final report
Technical Report
·
Wed Apr 25 00:00:00 EST 1984
·
OSTI ID:5827410
Development and demonstration of a Stirling/Rankine Heat Activated Heat Pump. Phase IIIB. Engine technology development testing. Final report
Technical Report
·
Thu Nov 01 00:00:00 EST 1984
·
OSTI ID:5827410