Title: Development and validation of a real-time SAFT-UT system for the inspection of light water reactor components. Semiannual report, April 1984-September 1984. Volume 1

Technical Report ·
OSTI ID:5764857

The Pacific Northwest Laboratory is working to design, fabricate, and evaluate a real-time flaw detection and characterization system based on the synthetic aperture focusing technique for ultrasonic testing (SAFT-UT). The system is for inservice inspection of light water reactor components. Included objectives of this program for the Nuclear Regulatory Commission are to develop procedures for system calibration and field operation, to validate the system through laboratory and field inspections, and to generate an engineering data base to support ASME Code acceptance of the technology. This process report covers the programmatic work from April 1984 through September 1984. 58 figs.

Research Organization:
Pacific Northwest Lab., Richland, WA (USA)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
5764857
Report Number(s):
NUREG/CR-4583-Vol.1; PNL-5822-Vol.1; ON: TI86010604
Country of Publication:
United States
Language:
English