Title: Light pipe - design for efficiency

Abstract

The high cost and availability of materials which are clear enough to transmit light without absorption has limited the idea of piping large-scale quantities of light. The light pipe uses the principle of Total Internal Reflection, with the light guided by very accurate prisms. The transmission of light directed into the end of a Light Pipe at an angle of less than 27.6 degrees is theoretically 100% efficient. The author describes its uses and advantages for lighting offices, cold storage areas, difficult access and hazardous areas, and for solar lighting. Future directions will be to improve the economics and accuracy of the technology. 4 references, 2 figures.

Authors:
Publication Date:
Research Org.:
TIR Systems, Ltd., Vancouver, British Columbia
OSTI Identifier:
5762635
Report Number(s):
CONF-850301-
Journal ID: CODEN: ENTED
Resource Type:
Conference
Resource Relation:
Journal Name: Energy Technol. (Wash., D.C.); (United States); Journal Volume: 12; Conference: 12. annual energy technology conference and exposition, Washington, DC, USA, 25 Mar 1985
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; 14 SOLAR ENERGY; 71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS; LIGHT PIPES; TECHNOLOGY ASSESSMENT; LIGHT TRANSMISSION; DESIGN; ECONOMICS; LIGHTING SYSTEMS; PRISMS; REFLECTIVITY; ENERGY SYSTEMS; OPTICAL PROPERTIES; PHYSICAL PROPERTIES; SURFACE PROPERTIES 320100* -- Energy Conservation, Consumption, & Utilization-- Buildings; 141000 -- Solar Collectors & Concentrators; 657005 -- Theoretical Physics-- Optics

Citation Formats

Hockey, S.N.. Light pipe - design for efficiency. United States: N. p., 1985. Web.
Hockey, S.N.. Light pipe - design for efficiency. United States.
Hockey, S.N.. 1985. "Light pipe - design for efficiency". United States. doi:.
@article{osti_5762635,
title = {Light pipe - design for efficiency},
author = {Hockey, S.N.},
abstractNote = {The high cost and availability of materials which are clear enough to transmit light without absorption has limited the idea of piping large-scale quantities of light. The light pipe uses the principle of Total Internal Reflection, with the light guided by very accurate prisms. The transmission of light directed into the end of a Light Pipe at an angle of less than 27.6 degrees is theoretically 100% efficient. The author describes its uses and advantages for lighting offices, cold storage areas, difficult access and hazardous areas, and for solar lighting. Future directions will be to improve the economics and accuracy of the technology. 4 references, 2 figures.},
doi = {},
journal = {Energy Technol. (Wash., D.C.); (United States)},
number = ,
volume = 12,
place = {United States},
year = 1985,
month = 8
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share:
  • Clamp induced stresses in FFTF piping are sufficiently large to require structural assessment. The basic principles and procedures used in analyzing FFTF piping at clamp support locations for compliance with ASME Code rules are given. Typical results from a three-dimensional shell finite element pipe model with clamp loads applied over the clamp/pipe contact area are shown. Analyses performed to categorize clamp induced piping loads as primary or secondary in nature are described. The ELCLAMP Computer Code, which performs analyses at clamp locations combining clamp induced stresses with stresses from overall piping system loads, is discussed. Grouping and enveloping methods tomore » reduce the number of individual clamp locations requiring analysis are described.« less
  • The objective of this program is the development of a gas fired warm air furnace of the highest practicable efficiency. A market survey indicated that the average furnace in the mid-to-late 1980's would have approximately 14.6 kW (50,000 Btu/hr) input.
  • Nondestructive assay (NDA) measurements of Transuranic (TRU) waste at Los Alamos National Laboratory (LANL) packed in Pipe-over-Pack Containers (POC) contain a number of complexities. The POC is highly attenuating to both gamma rays and neutrons which presents a difficult waste matrix for correct quantification of material in the container. Currently there are a number ofPOC containers at LANL that require evaluation for shipment to the Waste Isolation Pilot Plant (WIPP) in Carlsbad, NM. Updated data has been evaluated that finalizes the evaluation of characterizing Pipe-Over-Pack Containers. Currently at LANL, a single instrument has been used to explore the appropriateness ofmore » both passive neutron and quantitative gamma ray methods for measuring POC's. The passive neutron approach uses the Reals coincidence count rate to establish plutonium mass and other parameters of interest for TRU waste. The quantitative gamma ray method assumes a homogeneous distribution of radioactive source material with the surrounding material throughout the drum volume. Drums are assayed with a calibration based on the known density of the matrix. Both methods are supplemented by a simultaneous isotopic measurement using Multi-Group Analysis (MGA) to determine the plutonium isotopic composition. If MGA fails to provide a viable isotopic result Fixed Energy Response function Analysis with Multiple efficiencies (FRAM) has been used to replace the MGA results. Acceptable Knowledge (AK) may also be used in certain instances. This report will discuss the two methods in detail. Included in the discussion will be descriptions of the setup parameters and calibration techniques for the instrument. A number of test measurements have been performed to compare HENC data with certified historical data. Empty POCs loaded with known sources have also been measured to determine the viability of the technique. A comparison between calorimetry data, historical measurements and HENC data will also be performed. The conclusion will show that the current calibration on the HENC units is viable for analysis of POCs.« less
  • This paper discusses the computer-aided design of the piping and pipe supports of nuclear power plants. Hardware improvements have been made in the areas of man-machine communication, processing speed, and memory density. Topics considered include evolving design systems, application to current needs, safety-related small-bore piping and support design, as-built drawing review and reconciliation, large-bore pipe support design, snubber population reduction, and operating plant modifications. The improvements in man-machine communication hardware permit the designer to communicate with the computer in terms of pictures of elements of the design. The processing speed and memory density improvements enables the assembly of the designmore » on the machine.« less
  • The recent development of a light pipe makes it possible to separate a light source from the area to be illuminated. The paper reports on the light intensity and distribution for selected lamp/light pipe systems for use in commercial plant growth chambers, propagation rooms and tissue culture facilities.