Moisture measurements in residential attics containing radiant barriers
- Oak Ridge National Lab., TN (USA)
Tests were conducted by Oak Ridge National Laboratory researchers at three unoccupied research houses in Karns, Tennessee, to determine the effects of moisture condensation on the underside of perforated horizontal radiant barriers during the winter of 1987--88. An experimental plan called for the houses to be operated at high indoor relative humidities (45 and 55% at 70{degree}F), with data concerning the attic moisture conditions collected by both visual and instrument measurements. The testing showed that moisture went through a diurnal cycle. Moisture could condense on the bottom surface of a horizontal barrier in cold (below 35{degree}F) weather, but it could also dissipate to the attic air during a normal Tennessee winter afternoon, leaving the barrier dry. In long periods of subfreezing weather, all the condensation did not vaporize, as some remained on the surface through the day. However, the testing did show that the moisture cycle occurring on a perforated horizontal radiant barrier during a typical Tennessee winter did not appear to pose any structural, wet insulation, or stained ceiling problems to the Karns research houses, even though they were operated at higher than normal indoor relative humidities. Care should be taken in extrapolating the observations of this experimental work to areas with prolonged periods of subfreezing weather. The diurnal moisture cycle under a barrier may be different in colder climates. Further testing of horizontal barriers in colder climates is recommended. 21 refs., 44 figs., 11 tabs.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (USA); Oak Ridge National Lab., TN (USA)
- Sponsoring Organization:
- EPRI
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 5737521
- Report Number(s):
- EPRI-CU-6495
- Country of Publication:
- United States
- Language:
- English
Similar Records
Moisture measurements in single-family houses with attics containing radiant barriers
Heating energy measurements of single-family houses with attics containing radiant barriers in combustion with R-11 and R-30 ceiling insulation
Related Subjects
ATTICS
MOISTURE
MEASURING METHODS
HEAT TRANSFER
HUMIDITY
PERFORMANCE TESTING
PROGRESS REPORT
RESIDENTIAL BUILDINGS
THERMAL BARRIERS
THERMAL INSULATION
BUILDINGS
DOCUMENT TYPES
ENERGY TRANSFER
TESTING
320107* - Energy Conservation
Consumption
& Utilization- Building Systems- (1987-)