This report assesses stabilization issues concerning mixed plutonium-uranium oxides containing < 50 wt% Pu. It recommends that these materials be stored under a revision to DOE-STD-3013-96 ``Criteria for Preparing and Packaging Plutonium Metals and Oxides for Long-Term Storage,`` which addresses long-term storage of materials > 50 mass % Pu. Possible consequences of uranium substitution on thermal stabilization, specific surface areas, moisture readsorption behavior, loss-on-ignition analysis, and criticality safety of the oxide are examined and discussed.
- Research Organization:
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE Assistant Secretary for Human Resources and Administration, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 573281
- Report Number(s):
- LA-13236-MS; ON: DE98003070; TRN: 98:009160
- Resource Relation:
- Other Information: PBD: Nov 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characterization of Representative Materials in Support of Safe, Long Term Storage of Surplus Plutonium in DOE-STD-3013 Containers
Characterization of representative materials in support of safe, long term storage of surplus plutonium in DOE-STD-3013 containers
TECHNICAL BASIS FOR DOE STANDARD 3013 EQUIVALENCY SUPPORTING REDUCED TEMPERATURE STABILIZATION OF OXALATE-DERIVED PLUTONIUM OXIDE PRODUCED BY THE HB-LINE FACILITY AT SAVANNAH RIVER SITE
Technical Report
·
Fri Feb 15 00:00:00 EST 2013
·
OSTI ID:573281
+3 more
Characterization of representative materials in support of safe, long term storage of surplus plutonium in DOE-STD-3013 containers
Conference
·
Fri Jan 01 00:00:00 EST 2010
·
OSTI ID:573281
+1 more
TECHNICAL BASIS FOR DOE STANDARD 3013 EQUIVALENCY SUPPORTING REDUCED TEMPERATURE STABILIZATION OF OXALATE-DERIVED PLUTONIUM OXIDE PRODUCED BY THE HB-LINE FACILITY AT SAVANNAH RIVER SITE
Technical Report
·
Mon Jul 02 00:00:00 EDT 2012
·
OSTI ID:573281
+1 more