Detailed conceptual design of a high temperature glass pH electrode for geothermal applications. Final report, Task I
A modification of the planar electrode technology yielded prototype glass pH electrodes that can withstand the minimum test conditions of 250/sup 0/C and 5000 psi in an aqueous synthetic geothermal brine. Electrodes of this design can be made in volume at reasonable cost. In addition, an electrode holder has been designed and prototypes fabricated to permit laboratory testing in simulated geothermal brines of downhole conditions.
- Research Organization:
- Owens-Illinois, Inc., Toledo, OH (USA). Corporate Technology Div.
- DOE Contract Number:
- EY-76-C-06-1830
- OSTI ID:
- 5717380
- Report Number(s):
- RLO-1830-T3
- Country of Publication:
- United States
- Language:
- English
Similar Records
Detailed conceptual design of a high temperature glass pH electrode for geothermal applications. Final report. Task II
R and D, fabrication and testing of pH and CO/sub 2/ sensors for geothermal brines
Development of a high temperature pH electrode for geothermal fluids
Technical Report
·
Mon Sep 01 00:00:00 EDT 1980
·
OSTI ID:5717380
R and D, fabrication and testing of pH and CO/sub 2/ sensors for geothermal brines
Technical Report
·
Sun Mar 01 00:00:00 EST 1987
·
OSTI ID:5717380
+1 more
Development of a high temperature pH electrode for geothermal fluids
Journal Article
·
Tue May 01 00:00:00 EDT 1984
· J. Electrochem. Soc.; (United States)
·
OSTI ID:5717380