Previous testing by BSRI/SRTC/Raytheon indicated that the CLSM specified for the Tank 20 closure generates about 6 gallons (23 liters) of bleed water per cubic yard of material (0.76 m3).1 This amount to about 10 percent of the total mixing water. HLWE requested that the CLSM mix be optimized to reduce bleed water while maintaining flow. Elimination of bleed water from the CLSM mix specified for High-Level Waste Tank Closure will result in waste minimization, time savings and cost savings. Over thirty mixes were formulated and evaluated at the on-site Raytheon Test Laboratory. Improved low bleed water CLSM mixes were identified. Results are documented in this report.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
568611
Report Number(s):
WSRC-RP-97-271; ON: DE97053830; TRN: 98:002409
Resource Relation:
Other Information: PBD: 21 Apr 1997
Country of Publication:
United States
Language:
English

Similar Records

High performance CLSM field mixing and pumping test results
Technical Report · Wed May 14 00:00:00 EDT 1997 · OSTI ID:568611

High Performance Zero-Bleed CLSM/Grout Mixes for High-Level Waste Tank Closures Strategic Research and Development - FY99 Report
Technical Report · Fri Aug 11 00:00:00 EDT 2000 · OSTI ID:568611

Bleed water testing program for controlled low strength material
Technical Report · Tue Nov 12 00:00:00 EST 1996 · OSTI ID:568611