Title: Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods

Abstract

A total of 224 recent isolates of Mycobacterium tuberculosis from 163 patients selected to have multidrug resistance were tested against streptomycin (SM), isoniazid, rifampin, and ethambutol (EMB) by the rapid radiometric BACTEC method and two conventional proportion methods: the World Health Organization (WHO) method, using Lowenstein-Jensen medium; and the Veterans Administration reference laboratory for mycobacteria (VA) method, using Middlebrook 7H10 agar medium. The results were compared, focusing on the concentrations of the drugs in all three methods. Among the four drugs tested, most of the discrepancies in measured activity were observed with SM and EMB, generally because of differences in the drug concentrations used by the three methods. A 4-micrograms amount of SM in the BACTEC method was found to be slightly less active than 10 micrograms in the VA method and significantly more active than 4 micrograms of dihydrostreptomycin in the WHO method. With EMB, 2.5 micrograms in BACTEC was similar to 5 micrograms in the VA method and 2 micrograms in the WHO method, while 10 micrograms in the BACTEC method was found to be more active than 10 and 2 micrograms in the VA and WHO methods, respectively. To attain close agreement, drug concentrations used in themore » BACTEC method should be carefully selected when a comparison is to be made with any conventional method employed in a laboratory. Standardization of in vitro susceptibility testing is greatly needed to achieve uniformity among the test methods used to evaluate tuberculosis therapeutics.« less

Authors:
; ;
Publication Date:
OSTI Identifier:
5677467
Resource Type:
Journal Article
Resource Relation:
Journal Name: J. Clin. Microbiol.; (United States); Journal Volume: 6
Country of Publication:
United States
Language:
English
Subject:
59 BASIC BIOLOGICAL SCIENCES; ANTIBIOTICS; RADIOASSAY; MYCOBACTERIUM TUBERCULOSIS; DRUGS; INTERLABORATORY COMPARISONS; ISONIAZID; STREPTOMYCIN; TESTING; ANTI-INFECTIVE AGENTS; ANTIMICROBIAL AGENTS; BACTERIA; HYDRAZIDES; MICROORGANISMS; MYCOBACTERIUM; ORGANIC COMPOUNDS; ORGANIC NITROGEN COMPOUNDS; 550701* - Microbiology- Tracer Techniques

Citation Formats

Siddiqi, S.H., Hawkins, J.E., and Laszlo, A.. Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods. United States: N. p., 1985. Web.
Siddiqi, S.H., Hawkins, J.E., & Laszlo, A.. Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods. United States.
Siddiqi, S.H., Hawkins, J.E., and Laszlo, A.. 1985. "Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods". United States. doi:.
@article{osti_5677467,
title = {Interlaboratory drug susceptibility testing of Mycobacterium tuberculosis by a radiometric procedure and two conventional methods},
author = {Siddiqi, S.H. and Hawkins, J.E. and Laszlo, A.},
abstractNote = {A total of 224 recent isolates of Mycobacterium tuberculosis from 163 patients selected to have multidrug resistance were tested against streptomycin (SM), isoniazid, rifampin, and ethambutol (EMB) by the rapid radiometric BACTEC method and two conventional proportion methods: the World Health Organization (WHO) method, using Lowenstein-Jensen medium; and the Veterans Administration reference laboratory for mycobacteria (VA) method, using Middlebrook 7H10 agar medium. The results were compared, focusing on the concentrations of the drugs in all three methods. Among the four drugs tested, most of the discrepancies in measured activity were observed with SM and EMB, generally because of differences in the drug concentrations used by the three methods. A 4-micrograms amount of SM in the BACTEC method was found to be slightly less active than 10 micrograms in the VA method and significantly more active than 4 micrograms of dihydrostreptomycin in the WHO method. With EMB, 2.5 micrograms in BACTEC was similar to 5 micrograms in the VA method and 2 micrograms in the WHO method, while 10 micrograms in the BACTEC method was found to be more active than 10 and 2 micrograms in the VA and WHO methods, respectively. To attain close agreement, drug concentrations used in the BACTEC method should be carefully selected when a comparison is to be made with any conventional method employed in a laboratory. Standardization of in vitro susceptibility testing is greatly needed to achieve uniformity among the test methods used to evaluate tuberculosis therapeutics.},
doi = {},
journal = {J. Clin. Microbiol.; (United States)},
number = ,
volume = 6,
place = {United States},
year = 1985,
month =
}
  • A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with /sup 14/C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests resultsmore » reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations.« less
  • Direct-drug-susceptibility tests were performed on clinical specimens positive for acid-fast bacilli by either Ziehl-Neelsen or fluorochrome staining. The results of conventional agar dilution and a modified radiometric (BACTEC) method were compared. A total of 580 smear-positive specimens were tested by the BACTEC method at three separate sites. Three hundred and seventy-seven of these were culture positive for M. tuberculosis, and 343 (91%) yielded acceptable direct-susceptibility-test results. We used the conventional method to determine that 343 of 519 smear-positive specimens were culture positive for M. tuberculosis, and 212 (62%) produced acceptable results within 3 wks. Conventional results were reported in 3-4more » wks, while the time required to obtain results with the BACTEC method ranged from 5 to 21 days (average 11.5 days). Results indicate that the radiometric method provides reportable results more frequently with time savings as compared to the conventional method.« less
  • Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlationmore » among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis.« less
  • Pyrazinamide susceptibility testing of Mycobacterium tuberculosis requires an acid environment. By controlling the method of acidification and the quality and quantity of the inoculum, the test can be performed with the BACTEC radiometric system (Johnston Laboratories, Towson, Md.). We acidified BACTEC 7H12 medium with buffered phosphoric acid and adjusted the test inoculum to 1/10 of that usually employed in BACTEC protocols; after 5 days of growth we correctly identified 36 of 36 strains susceptible to 50 micrograms of pyrazinamide per ml. All 18 resistant strains were classified as pyrazinamide resistant. (Susceptibility or resistance had been determined by standard plate assays.)more » The test was able to detect small resistant populations in artificial mixtures of 1 or 2% resistant bacteria with a susceptible strain (10 mixtures each). We tested 70 M. tuberculosis strains in acidified BACTEC 7H12 medium and by the plate dilution test at pH 5.5. All strains grew in the BACTEC medium, but three strains failed to grow on plates and were not tested further; the results of both methods agreed for the remaining strains.« less
  • A radiometric method for testing the susceptibility of Mycobacterium tuberculosis to pyrazinamide in egg-yolk-enriched 12A medium (pH 5.5) is described. We obtained 100% agreement between the 7H10 agar method with 25 microgram of pyrazinamide per ml and the modified radiometric method with a drug concentration of 50 microgram/ml in tests of 90 clinical isolates.