Title: Extreme-ultraviolet beam-foil spectroscopy of highly ionized neon and argon. Final report

Abstract

A study of the extreme-ultraviolet radiation emitted by ion beams of highly ionized neon and argon after passage through thin foils was conducted at the variable-energy cyclotron at Texas AandM University. A grazing-incidence spectrometer was equipped with a position-sensitive microchannel plate (MCP) detector, which improved the detection efficiency by two orders of magnitude. The position information of the MCP was determined to be linear over 90% of the 50-mm-wide detector. Spectra-spanning regions of over 100 angstroms were accumulated at a resolution of less than 1 angstrom. A wavelength calibration based on a second-order equation of spectrometer position was found to result in an accuracy of + 0.1 angstroms.

Authors:
Publication Date:
Research Org.:
Air Force Weapons Lab., Kirtland AFB, NM (USA)
OSTI Identifier:
5662144
Report Number(s):
AD-A-185197/1/XAB; AFWL-TR-87-26
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
74 ATOMIC AND MOLECULAR PHYSICS; 37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; ARGON IONS; MULTICHARGED IONS; ION BEAMS; ION SPECTROSCOPY; FAR ULTRAVIOLET RADIATION; NEON IONS; THIN FILMS; CALIBRATION; DOPPLER EFFECT; BEAMS; CHARGED PARTICLES; ELECTROMAGNETIC RADIATION; FILMS; IONS; RADIATIONS; SPECTROSCOPY; ULTRAVIOLET RADIATION; 640304* - Atomic, Molecular & Chemical Physics- Collision Phenomena; 400102 - Chemical & Spectral Procedures

Citation Formats

Demarest, J A. Extreme-ultraviolet beam-foil spectroscopy of highly ionized neon and argon. Final report. United States: N. p., 1987. Web.
Demarest, J A. Extreme-ultraviolet beam-foil spectroscopy of highly ionized neon and argon. Final report. United States.
Demarest, J A. 1987. "Extreme-ultraviolet beam-foil spectroscopy of highly ionized neon and argon. Final report". United States.
@article{osti_5662144,
title = {Extreme-ultraviolet beam-foil spectroscopy of highly ionized neon and argon. Final report},
author = {Demarest, J A},
abstractNote = {A study of the extreme-ultraviolet radiation emitted by ion beams of highly ionized neon and argon after passage through thin foils was conducted at the variable-energy cyclotron at Texas AandM University. A grazing-incidence spectrometer was equipped with a position-sensitive microchannel plate (MCP) detector, which improved the detection efficiency by two orders of magnitude. The position information of the MCP was determined to be linear over 90% of the 50-mm-wide detector. Spectra-spanning regions of over 100 angstroms were accumulated at a resolution of less than 1 angstrom. A wavelength calibration based on a second-order equation of spectrometer position was found to result in an accuracy of + 0.1 angstroms.},
doi = {},
url = {https://www.osti.gov/biblio/5662144}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jun 01 00:00:00 EDT 1987},
month = {Mon Jun 01 00:00:00 EDT 1987}
}