skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Welding procedure specification. Supplement 1. Records of procedure qualification tests. Gas tungsten arc (DC) welding to aluminum alloys 1XXX and 3003 to 6XXX. [1060, 1100, and 3003 to 6061 and 6063]

Technical Report ·
OSTI ID:5501266

Procedure WPS-2207 is qualified under Section IX of the ASME Boiler and Pressure Vessel Code for gas tungsten arc welding of aluminum alloys 1060, 1100, and 3003 (P-21) to 6061 and 6063 (P-23), in thickness range 0.125 to 0.516; filler metal is ER4043 (F-23); current is direct; shielding gas is helium.

Research Organization:
Oak Ridge National Lab., TN (USA)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
5501266
Report Number(s):
ORNL/M-41/S1; ON: DE86012559
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products