Long term optimum performance/corrosion tests of combustion modifications for utility boilers. Host site: Columbus and Southern Ohio Electric Company, Conesville No. 5. Final report Jan 1979-Nov 1981
Technical Report
·
OSTI ID:5472014
The report gives results of part of a study of corrosion in large utility boilers firing high-sulfur coal, as possibly affected by combustion modifications (CMs) for decreased nitrogen oxide (NOx) emissions. During the first part of this study, each boiler was characterized to learn the short term effects of various CMs on boiler operation and emissions. Later, a Level 1 environmental assessment (EA) of boiler operation was performed, followed by tests to measure corrosion rates in the furnace. For the nearly 2-year study, waterwall corrosion rates (measured ultrasonically) were similar to rates under normal operation at about 1-2 mils/yr.
- Research Organization:
- Exxon Research and Engineering Co., Florham Park, NJ (USA)
- OSTI ID:
- 5472014
- Report Number(s):
- PB-84-102698
- Country of Publication:
- United States
- Language:
- English
Similar Records
Long-term optimum performance/corrosion tests of combustion modifications for utility boilers. host site: Louisville Gas and Electric Company, Mill Creek No. 3
Control of utility boiler and gas turbine pollutant emissions by combustion modification--phase ii. Final report, June 1976-June 1979
Computational Modeling and Assessment Of Nanocoatings for Ultra Supercritical Boilers
Technical Report
·
Sun Jan 01 00:00:00 EST 1984
·
OSTI ID:5472014
Control of utility boiler and gas turbine pollutant emissions by combustion modification--phase ii. Final report, June 1976-June 1979
Technical Report
·
Sun Mar 01 00:00:00 EST 1981
·
OSTI ID:5472014
Computational Modeling and Assessment Of Nanocoatings for Ultra Supercritical Boilers
Other
·
Mon Apr 11 00:00:00 EDT 2011
·
OSTI ID:5472014
Related Subjects
42 ENGINEERING
BOILERS
CORROSION
MODIFICATIONS
AIR POLLUTION CONTROL
COMBUSTION PRODUCTS
ENVIRONMENTAL IMPACTS
FLUE GAS
INDUSTRIAL WASTES
NITROGEN OXIDES
SAMPLING
CHALCOGENIDES
CHEMICAL REACTIONS
CONTROL
GASEOUS WASTES
NITROGEN COMPOUNDS
OXIDES
OXYGEN COMPOUNDS
POLLUTION CONTROL
WASTES
421000* - Engineering- Combustion Systems
BOILERS
CORROSION
MODIFICATIONS
AIR POLLUTION CONTROL
COMBUSTION PRODUCTS
ENVIRONMENTAL IMPACTS
FLUE GAS
INDUSTRIAL WASTES
NITROGEN OXIDES
SAMPLING
CHALCOGENIDES
CHEMICAL REACTIONS
CONTROL
GASEOUS WASTES
NITROGEN COMPOUNDS
OXIDES
OXYGEN COMPOUNDS
POLLUTION CONTROL
WASTES
421000* - Engineering- Combustion Systems