Title: Internal irradiation from nuclear medicine investigations: A comparison between effective dose equivalent and effective dose

Abstract

ICRP Publication 60 (1990) proposes a partially revised method to calculate effective dose, a quantity previously defined in ICRP Publication 26 (1977) as effective dose equivalent. The authors applied these two different approaches to calculate the effective dose equivalent and the effective dose, in the case of internal irradiations from the most common nuclear medicine investigations. The results show clear differences between the two examined quantities, even if the differences are not statistically significant. 5 refs., 4 tabs.

Authors:
; ;  [1]
  1. Ospedale S. Anna, Como (Italy)
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
54461
Resource Type:
Journal Article
Journal Name:
Health Physics
Additional Journal Information:
Journal Volume: 67; Journal Issue: 4; Other Information: PBD: Oct 1994
Country of Publication:
United States
Language:
English
Subject:
56 BIOLOGY AND MEDICINE, APPLIED STUDIES; DOSE EQUIVALENTS; CALCULATION METHODS; RADIATION DOSES

Citation Formats

Ostinelli, A, Monti, A, and Milan, M. Internal irradiation from nuclear medicine investigations: A comparison between effective dose equivalent and effective dose. United States: N. p., 1994. Web. doi:10.1097/00004032-199410000-00011.
Ostinelli, A, Monti, A, & Milan, M. Internal irradiation from nuclear medicine investigations: A comparison between effective dose equivalent and effective dose. United States. https://doi.org/10.1097/00004032-199410000-00011
Ostinelli, A, Monti, A, and Milan, M. 1994. "Internal irradiation from nuclear medicine investigations: A comparison between effective dose equivalent and effective dose". United States. https://doi.org/10.1097/00004032-199410000-00011.
@article{osti_54461,
title = {Internal irradiation from nuclear medicine investigations: A comparison between effective dose equivalent and effective dose},
author = {Ostinelli, A and Monti, A and Milan, M},
abstractNote = {ICRP Publication 60 (1990) proposes a partially revised method to calculate effective dose, a quantity previously defined in ICRP Publication 26 (1977) as effective dose equivalent. The authors applied these two different approaches to calculate the effective dose equivalent and the effective dose, in the case of internal irradiations from the most common nuclear medicine investigations. The results show clear differences between the two examined quantities, even if the differences are not statistically significant. 5 refs., 4 tabs.},
doi = {10.1097/00004032-199410000-00011},
url = {https://www.osti.gov/biblio/54461}, journal = {Health Physics},
number = 4,
volume = 67,
place = {United States},
year = {Sat Oct 01 00:00:00 EDT 1994},
month = {Sat Oct 01 00:00:00 EDT 1994}
}