Title: X-ray computed tomography for structural ceramic applications: Beam hardening corrections

Technical Report ·
OSTI ID:5421554

Beam hardening (BH), caused by the energy dependence of x-ray attenuation in materials, reduces the reliability of images generated by computed tomographic (CT) when polychromatic x-ray sources are used. The magnitude of the BH effect was calculated, and four different approaches to BH correction for CT imaging of ceramics were investigated: the ''water bag'' approach, prehardening of the beam by use of a filter, linearization correction, and dual-energy methods. The dual-energy approach appears to be a promising means of BH correction for CT imaging of ceramics. 23 refs., 22 figs.

Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
5421554
Report Number(s):
ANL-87-24; ON: DE88005891
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English

Similar Records

Segmentation-free empirical beam hardening correction for CT
Journal Article · Sun Feb 15 00:00:00 EST 2015 · Medical Physics · OSTI ID:5421554

Beam-hardening correction methods for polychromatic x-ray CT scanners used to characterize structural ceramics
Conference · Tue Jul 01 00:00:00 EDT 1986 · OSTI ID:5421554

Beam Hardening Corrections in Quantitative Computed Tomography