skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: TRAC-PD2 posttest analysis of CCTF Test C1-16 (Run 025). [Cylindrical Core Test Facility]

Abstract

The TRAC-PD2 code version was used to analyze CCTF Test C1-16 (Run 025). The results indicate that the core heater rod temperatures, the liquid mass in the vessel, and differential pressures in the primary loop are predicted well, but the void fraction distribution in the core and water accumulation in the upper plenum are not in good agreement with the data.

Authors:
Publication Date:
Research Org.:
Los Alamos Scientific Lab., NM (USA)
OSTI Identifier:
5391897
Report Number(s):
NUREG/CR-1991; LA-8741-MS
ON: TI85015982
DOE Contract Number:  
W-7405-ENG-36
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; REACTOR SAFETY EXPERIMENTS; COMPUTER CALCULATIONS; COMPUTER CODES; ECCS; PUMPS; SIMULATION; STEAM GENERATORS; T CODES; BOILERS; ENGINEERED SAFETY SYSTEMS; REACTOR PROTECTION SYSTEMS; VAPOR GENERATORS; 220900* - Nuclear Reactor Technology- Reactor Safety

Citation Formats

Sugimoto, J. TRAC-PD2 posttest analysis of CCTF Test C1-16 (Run 025). [Cylindrical Core Test Facility]. United States: N. p., 1981. Web.
Sugimoto, J. TRAC-PD2 posttest analysis of CCTF Test C1-16 (Run 025). [Cylindrical Core Test Facility]. United States.
Sugimoto, J. Fri . "TRAC-PD2 posttest analysis of CCTF Test C1-16 (Run 025). [Cylindrical Core Test Facility]". United States.
@article{osti_5391897,
title = {TRAC-PD2 posttest analysis of CCTF Test C1-16 (Run 025). [Cylindrical Core Test Facility]},
author = {Sugimoto, J.},
abstractNote = {The TRAC-PD2 code version was used to analyze CCTF Test C1-16 (Run 025). The results indicate that the core heater rod temperatures, the liquid mass in the vessel, and differential pressures in the primary loop are predicted well, but the void fraction distribution in the core and water accumulation in the upper plenum are not in good agreement with the data.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1981},
month = {5}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share: