Energy conversion alternatives study (ECAS). integrated coal gasifier/molten carbonate fuel cell powerplant conceptual design and implementation assessment. Final report on phase 2
Technical Report
·
OSTI ID:5384007
This report describes results of an Energy Conversion Alternatives Study (ECAS) Phase II conceptual design and implementation assessment study of an integrated coal gasifier/molten carbonate fuel cell power plant. Conceptual designs are prepared in sufficient detail to describe anticipated power plant performance, capital cost, cost of electricity, natural resource requirements, and environmental impact. This report is comprised of the following: a description of the conceptual design; an estimate of the design characteristics; the technology and design status; a description of a research development and demonstration plan; and a discussion of factors affecting implementation.
- Research Organization:
- United Technologies Corp., South Windsor, Conn. (USA). Power Systems Div.; Burns and Roe, Inc., Oradell, N.J. (USA); Institute of Gas Technology, Chicago, Ill. (USA)
- DOE Contract Number:
- NAS3-19586
- OSTI ID:
- 5384007
- Report Number(s):
- PB-270016; FCR-0237
- Country of Publication:
- United States
- Language:
- English
Similar Records
Energy conversion alternatives study (ECAS), Phase 2. Volume 1: summary and combined gas steam turbine plant with an integrated low-btu gasifier. Final report
Energy conversion alternatives study (ECAS), phase 2. Volume 1: executive summary. Final report
Energy Conversion Alternatives Study (ECAS), Westinghouse Phase 1. Vol. X11: fuel cells. Final report. [Phosphoric acid, potassium hydroxide, molten carbonate, and stabilized zirconia electrolytes are compared]
Technical Report
·
Mon Nov 01 00:00:00 EST 1976
·
OSTI ID:5384007
Energy conversion alternatives study (ECAS), phase 2. Volume 1: executive summary. Final report
Technical Report
·
Wed Dec 01 00:00:00 EST 1976
·
OSTI ID:5384007
Energy Conversion Alternatives Study (ECAS), Westinghouse Phase 1. Vol. X11: fuel cells. Final report. [Phosphoric acid, potassium hydroxide, molten carbonate, and stabilized zirconia electrolytes are compared]
Technical Report
·
Thu Feb 12 00:00:00 EST 1976
·
OSTI ID:5384007
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
30 DIRECT ENERGY CONVERSION
FOSSIL-FUEL POWER PLANTS
COST
DESIGN
ENVIRONMENTAL IMPACTS
FUEL CELL POWER PLANTS
COAL GASIFICATION
PERFORMANCE
POWER GENERATION
TECHNOLOGY ASSESSMENT
GASIFICATION
POWER PLANTS
THERMAL POWER PLANTS
200100* - Fossil-Fueled Power Plants- Power Plants & Power Generation
300501 - Fuel Cells- Design & Development
30 DIRECT ENERGY CONVERSION
FOSSIL-FUEL POWER PLANTS
COST
DESIGN
ENVIRONMENTAL IMPACTS
FUEL CELL POWER PLANTS
COAL GASIFICATION
PERFORMANCE
POWER GENERATION
TECHNOLOGY ASSESSMENT
GASIFICATION
POWER PLANTS
THERMAL POWER PLANTS
200100* - Fossil-Fueled Power Plants- Power Plants & Power Generation
300501 - Fuel Cells- Design & Development