Intensity measurement of high-energy heavy ions at the GSI facility
Abstract
The intensity of the high-energy heavy ion beam, extracted from the heavy ion synchrotron (SIS) at the GSI, Darmstadt, is determined with three types of detectors: scintillator counters, ionisation chambers (ICs), and secondary electron monitors (SEMs). The accuracy of the ICs, compared to a general formula, is about 25{percent}; for the SEMs it is within a factor of two. Intensity limits for the IC are measured. A SQUID-based current comparator is in preparation for an absolute determination of the primary ion current. {copyright} {ital 1997 American Institute of Physics.}
- Authors:
-
- Gesellschaft fuer Schwerlonenforschung, Planckstrasse 1, D-64291 Darmstadt (Germany)
- Publication Date:
- OSTI Identifier:
- 526819
- Report Number(s):
- CONF-9605173-
Journal ID: APCPCS; ISSN 0094-243X; TRN: 97:016899
- Resource Type:
- Journal Article
- Journal Name:
- AIP Conference Proceedings
- Additional Journal Information:
- Journal Volume: 390; Journal Issue: 1; Conference: 7. workshop on beam instrumentation, Argonne, IL (United States), 6-9 May 1996; Other Information: PBD: Jan 1997
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 43 PARTICLE ACCELERATORS; 44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; HEAVY ION ACCELERATORS; BEAM MONITORING; BEAM MONITORS; DESIGN; IONIZATION CHAMBERS; SCINTILLATION COUNTERS; MEV RANGE; GEV RANGE; NANO AMP BEAM CURRENTS; SQUID DEVICES
Citation Formats
Forck, P, Heeg, P, Kernphysikalische Detektoren, Niedergartenweg 15, D-64331 Weiterstadt, and Peters, A. Intensity measurement of high-energy heavy ions at the GSI facility. United States: N. p., 1997.
Web. doi:10.1063/1.52298.
Forck, P, Heeg, P, Kernphysikalische Detektoren, Niedergartenweg 15, D-64331 Weiterstadt, & Peters, A. Intensity measurement of high-energy heavy ions at the GSI facility. United States. https://doi.org/10.1063/1.52298
Forck, P, Heeg, P, Kernphysikalische Detektoren, Niedergartenweg 15, D-64331 Weiterstadt, and Peters, A. 1997.
"Intensity measurement of high-energy heavy ions at the GSI facility". United States. https://doi.org/10.1063/1.52298.
@article{osti_526819,
title = {Intensity measurement of high-energy heavy ions at the GSI facility},
author = {Forck, P and Heeg, P and Kernphysikalische Detektoren, Niedergartenweg 15, D-64331 Weiterstadt and Peters, A},
abstractNote = {The intensity of the high-energy heavy ion beam, extracted from the heavy ion synchrotron (SIS) at the GSI, Darmstadt, is determined with three types of detectors: scintillator counters, ionisation chambers (ICs), and secondary electron monitors (SEMs). The accuracy of the ICs, compared to a general formula, is about 25{percent}; for the SEMs it is within a factor of two. Intensity limits for the IC are measured. A SQUID-based current comparator is in preparation for an absolute determination of the primary ion current. {copyright} {ital 1997 American Institute of Physics.}},
doi = {10.1063/1.52298},
url = {https://www.osti.gov/biblio/526819},
journal = {AIP Conference Proceedings},
number = 1,
volume = 390,
place = {United States},
year = {Wed Jan 01 00:00:00 EST 1997},
month = {Wed Jan 01 00:00:00 EST 1997}
}
Other availability
Save to My Library