Symmetrical. pi. and T attenuators: design data for component power dissipation and resistance
Technical Report
·
OSTI ID:5250783
The equations relevant to the selection of resistor values for symmetrical ..pi.. and T attenuator networks are presented. Equations defining the percentage of input power dissipated in each resistor of the network are derived. The dual aspects of symmetrical ..pi.. and T attenuators are discussed and the above results are summarized in easy to use graphical form.