Title: Investigation criteria for dosimetry results comparisons

Journal Article · · Radiation Protection Management; (United States)
OSTI ID:5228020
 [1]
  1. Duke Power Co., Oconee Nuclear Station, Seneca, SC (US)

This paper reports that the Oconee Nuclear Station, like most nuclear facilities, monitors its personnel with two types of dosimeters: a thermoluminescent dosimeter (TLD), which is normally used for determining the official dose equivalent, and a pocket ionization chamber (PIC), which is used to estimate exposure for control purposes. At Oconee, the results obtained from the two types of dosimeters are compared on a monthly basis as a part of the routine exchange and processing of worker TLDs. Each worker's TLD result is compared to the sum of the PIC dose estimates for the month that the TLD was used. The TLD result is accepted as the official dose equivalent for the month if the comparison results are within the tolerance limits specified by the criteria. An out-of-tolerance comparison requires investigation, which consists of performance tests of the dosimetry involved and reviews of exposure records. Adjustments to a worker's official dose equivalent are made when warranted by an investigation.

OSTI ID:
5228020
Journal Information:
Radiation Protection Management; (United States), Vol. 1:2; ISSN 0740-0640
Country of Publication:
United States
Language:
English