skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Modeling of integrated environmental control systems for coal-fired power plants: Conventional froth flotation for the IEC coal cleaning plant model

Technical Report ·
DOI:https://doi.org/10.2172/5178339· OSTI ID:5178339

This report describes the addition of a conventional froth flotation circuit into the FORTRAN coal cleaning module of the Integrated Environmental Control (IEC) model. The purpose of this modification is to include froth flotation as an option to clean the coal fines. The current model has three beneficiation: levels (2, 3, and 4) in which different streams are washed by specific gravity equipment. Level 2 washes only the coarse stream. Level 3 washes the coarse and medium streams. Level 4 washes the coarse, medium, and fine streams. This modification adds a fifth level, which uses specific gravity equipment to wash the coarse and medium streams and froth flotation equipment for the fine stream. The specific size fractions in each stream are specified by the model user. As before, the model optimizes the yield of each circuit in order to achieve a target coal quality for the cleaned coal product.

Research Organization:
Carnegie-Mellon Univ., Pittsburgh, PA (United States). Center for Energy and Environmental Studies
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC22-87PC79864
OSTI ID:
5178339
Report Number(s):
DOE/PC/79864-5; ON: DE92016061
Country of Publication:
United States
Language:
English