An automated personal computer based CAMAC data acquisition system is being implemented on the DIII-D neutral beamlines for certain diagnostics. The waterflow calorimetry (WFC) diagnostic is the first system to be upgraded. It includes data acquisition by a Macintosh II computer containing a National Instruments IEEE-488 card, and running their LabView software. Macintosh to CAMAC communications are carried out through an IEEE-488 crate controller. The Doppler shift spectroscopy, residual gas analysis, and armor tile infrared image diagnostics will be modified in similar ways. To reduce the demand for Macintosh CPU time, the extensive serial high-way data activity is performed by means of a new Kinetic Systems 3982 List sequencing Crate Controller dedicated to these operations. A simple Local Area Network file server is used to store data from all diagnostics together, and in a format readable by a standard commercial database. This reduces the problem of redundant data storage and allows simpler inter-diagnostic analysis. 3 refs., 4 figs.
- Research Organization:
- General Atomics, San Diego, CA (USA)
- Sponsoring Organization:
- DOE/ER
- DOE Contract Number:
- AC03-89ER51114
- OSTI ID:
- 5146949
- Report Number(s):
- GA-A-19757; CONF-891007-104; ON: DE90004100; TRN: 90-001547
- Resource Relation:
- Conference: 13. IEEE symposium on fusion engineering, Knoxville, TN (USA), 2-6 Oct 1989
- Country of Publication:
- United States
- Language:
- English
Similar Records
A graphical user-interface-driven waveform data acquisition and analysis system
A Camac-VME-MacIntosh data acquisition system for nuclear experiments
Related Subjects
DATA ACQUISITION SYSTEMS
DESIGN
PLASMA DIAGNOSTICS
APPLE COMPUTERS
CAMAC SYSTEM
COMPUTER ARCHITECTURE
PERSONAL COMPUTERS
COMPUTERS
DIGITAL COMPUTERS
ELECTRONIC CIRCUITS
MICROCOMPUTERS
MICROELECTRONIC CIRCUITS
MICROPROCESSORS
700102* - Fusion Energy- Plasma Research- Diagnostics