skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Water chemistry of breeder reactor steam generators. [LMFBR]

Conference ·
OSTI ID:5061826

The water quality requirements will be described for breeder reactor steam generators, as well as specifications for balance of plant protection. Water chemistry details will be discussed for the following power plant conditions: feedwater and recirculation water at above and below 5% plant power, refueling or standby, makeup water, and wet layup. Experimental data will be presented from tests which included a departure from nucleate boiling experiment, the Few Tube Test, with a seven tube evaporator and three tube superheater, and a verification of control and on-line measurement of sodium ion in the ppB range. Sampling and instrumentation requirements to insure adherence to the specified water quality will be described. Evaporator cleaning criteria and data from laboratory testing of chemical cleaning solutions with emphasis on flow, chemical composition, and temperature will be discussed.

Research Organization:
General Electric Co., Sunnyvale, CA (USA). Advanced Reactor Systems Dept.
DOE Contract Number:
AT03-76SF70030
OSTI ID:
5061826
Report Number(s):
GEFR-SP-221; CONF-801036-3; TRN: 80-016018
Resource Relation:
Conference: Special topical meeting - materials performance in nuclear steam generators, St Petersburg Beach, FL, USA, 6 Oct 1980
Country of Publication:
United States
Language:
English