Title: Plutonium nitrate bottle counter manual

Abstract

A neutron coincidence counter has been designed for plutonium nitrate assay in large storage bottles. This assay system can be used in the reprocessing plant or in the nitrate-to-oxide conversion facility. The system is based on the family of neutron detectors similar to the high-level neutron coincidence counter. This manual describes the system and gives performance and calibration parameters for typical applications. 4 references, 11 figures, 9 tables.

Authors:
; ;
Publication Date:
Research Org.:
Los Alamos National Lab., NM (USA)
OSTI Identifier:
5032927
Report Number(s):
LA-10009-M; ISPO-203
ON: DE84011020
DOE Contract Number:  
W-7405-ENG-36
Resource Type:
Technical Report
Resource Relation:
Other Information: Portions are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; COINCIDENCE CIRCUITS; SPECIFICATIONS; HE-3 COUNTERS; PLUTONIUM NITRATES; RADIOMETRIC ANALYSIS; CALIBRATION; MANUALS; NEUTRON DETECTION; SPONTANEOUS FISSION; ACTINIDE COMPOUNDS; CHEMICAL ANALYSIS; DECAY; DETECTION; DOCUMENT TYPES; ELECTRONIC CIRCUITS; FISSION; MEASURING INSTRUMENTS; NEUTRON DETECTORS; NITRATES; NITROGEN COMPOUNDS; NUCLEAR REACTIONS; OXYGEN COMPOUNDS; PLUTONIUM COMPOUNDS; PROPORTIONAL COUNTERS; QUANTITATIVE CHEMICAL ANALYSIS; RADIATION DETECTION; RADIATION DETECTORS; TRANSURANIUM COMPOUNDS; 440101* - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments; 400103 - Radiometric & Radiochemical Procedures- (-1987)

Citation Formats

Menlove, H O, Adams, E L, and Holbrooks, O R. Plutonium nitrate bottle counter manual. United States: N. p., 1984. Web. doi:10.2172/5032927.
Menlove, H O, Adams, E L, & Holbrooks, O R. Plutonium nitrate bottle counter manual. United States. https://doi.org/10.2172/5032927
Menlove, H O, Adams, E L, and Holbrooks, O R. Thu . "Plutonium nitrate bottle counter manual". United States. https://doi.org/10.2172/5032927. https://www.osti.gov/servlets/purl/5032927.
@article{osti_5032927,
title = {Plutonium nitrate bottle counter manual},
author = {Menlove, H O and Adams, E L and Holbrooks, O R},
abstractNote = {A neutron coincidence counter has been designed for plutonium nitrate assay in large storage bottles. This assay system can be used in the reprocessing plant or in the nitrate-to-oxide conversion facility. The system is based on the family of neutron detectors similar to the high-level neutron coincidence counter. This manual describes the system and gives performance and calibration parameters for typical applications. 4 references, 11 figures, 9 tables.},
doi = {10.2172/5032927},
url = {https://www.osti.gov/biblio/5032927}, journal = {},
number = ,
volume = ,
place = {United States},
year = {1984},
month = {3}
}