Title: Performance characteristics of large aperture, ten-cell, atmospheric pressure isobutane Cherenkov counters

Technical Report ·
DOI:https://doi.org/10.2172/5016084· OSTI ID:5016084

Two large aperture, 10 cell atmospheric-pressure isobutane Cherenkov counters were designed and constructed for a SLAC streamer chamber experiment. The rejection efficiencies for a 9 GeV/c ..pi../sup -/ were measured to be 99.838 +- .006% and 99.717 +- 008% for the two counters. The design details and performance characteristics are discussed.

Research Organization:
Michigan State Univ., East Lansing (USA). Dept. of Physics; Tufts Univ., Medford, MA (USA). Dept. of Physics
DOE Contract Number:
AS02-77ER14529
OSTI ID:
5016084
Report Number(s):
DOE/ER/14529-1; TRN: 80-017948
Country of Publication:
United States
Language:
English

Similar Records

A method for calculating the efficiency of large aperture gas Cherenkov counters
Conference · Fri Feb 01 00:00:00 EST 1985 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:5016084

The CLAS12 High Threshold Cherenkov Counter
Journal Article · Sat Jul 11 00:00:00 EDT 2020 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:5016084

A Rich Detector with Two Stage Gas Amplification at Atmospheric Pressure
Journal Article · Fri Apr 01 00:00:00 EST 1994 · Nuclear Instruments and Methods A · OSTI ID:5016084