Title: APT Blanket System Loss-of-Flow Accident (LOFA) Analysis Based on Initial Conceptual Design - Case 1: with Beam Shutdown and Active RHR

Abstract

This report is one of a series of reports that document normal operation and accident simulations for the Accelerator Production of Tritium (APT) blanket heat removal system. These simulations were performed for the Preliminary Safety Analysis Report.

Authors:
Publication Date:
Research Org.:
Savannah River Site (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
4893
Report Number(s):
WSRC-TR-98-0058
TRN: US0101561
DOE Contract Number:  
AC09-96SR18500
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 7 Oct 1998
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ACCELERATORS; LOSS OF FLOW; PRODUCTION; SAFETY ANALYSIS; SHUTDOWN; TRITIUM; RHR SYSTEMS; COMPUTERIZED SIMULATION; BREEDING BLANKETS

Citation Formats

Hamm, L.L. APT Blanket System Loss-of-Flow Accident (LOFA) Analysis Based on Initial Conceptual Design - Case 1: with Beam Shutdown and Active RHR. United States: N. p., 1998. Web. doi:10.2172/4893.
Hamm, L.L. APT Blanket System Loss-of-Flow Accident (LOFA) Analysis Based on Initial Conceptual Design - Case 1: with Beam Shutdown and Active RHR. United States. doi:10.2172/4893.
Hamm, L.L. Wed . "APT Blanket System Loss-of-Flow Accident (LOFA) Analysis Based on Initial Conceptual Design - Case 1: with Beam Shutdown and Active RHR". United States. doi:10.2172/4893. https://www.osti.gov/servlets/purl/4893.
@article{osti_4893,
title = {APT Blanket System Loss-of-Flow Accident (LOFA) Analysis Based on Initial Conceptual Design - Case 1: with Beam Shutdown and Active RHR},
author = {Hamm, L.L.},
abstractNote = {This report is one of a series of reports that document normal operation and accident simulations for the Accelerator Production of Tritium (APT) blanket heat removal system. These simulations were performed for the Preliminary Safety Analysis Report.},
doi = {10.2172/4893},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1998},
month = {10}
}