Title: DETECTION LEVEL OF THE FILM BADGE SYSTEM

Technical Report ·
OSTI ID:4818055

Improvement in the calibration system and installation of automatic processing equipment has contributed to the over-all accuracy of the film badge system and reduction of detection level. However, the largest contribution is derived from the ability of the film emulsion to record measurable densities at lower dose levels. Previously the detection level was quoted as 40 mr at about the 95% confidence level for 502 film emulsion. A statistical study of 508 emulsion response data collected from "production": batches indicate the detection level of the film badge system is now approximately 15 mr at the 90% corfidence level considering normal distribution of density-dose values for the 30 mr calibration level. With thirteen routine badge periods per year, the annual detection level is approximately 195 mr for penetrating gamma radiation. (auth)

Research Organization:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
DOE Contract Number:
AT(45-1)-1350
NSA Number:
NSA-16-019178
OSTI ID:
4818055
Report Number(s):
HW-67697
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-62
Country of Publication:
United States
Language:
English