HIGH LEVEL NEUTRON FLUX MONITOR FOR REACTOR USE
Technical Report
·
OSTI ID:4811385
Reliable flux monitoring for nuclear reactors is provided by an instrument that measures currents between 1 x 10/sup -9/ and 3 x 10/sup -4/ amp from a neutron-sensitive ion chamber. Three adjustable high level alarms are available. The average failure frequency for this circuit has been about one per seven years. (auth)
- Research Organization:
- Du Pont de Nemours (E.I.) & Co. Savannah River Lab., Aiken, S.C.
- DOE Contract Number:
- AT(07-2)-1
- NSA Number:
- NSA-16-028360
- OSTI ID:
- 4811385
- Report Number(s):
- DP-693
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-62
- Country of Publication:
- United States
- Language:
- English
Similar Records
INSTRUMENTATION FOR A SUBCRITICAL HOMOGENEOUS SUSPENSION REACTOR. IIIA. THE MONITORING OF LOW NEUTRON FLUX BY MEANS OF FAST PULSE-COUNTING CHANNELS
INSTRUMENTATION FOR A SUBCRITICAL HOMOGENEOUS SUSPENSION REACTOR. IIIB. THE MONITORING OF HIGH NEUTRON FLUX WITH THE AID OF AN ELECTROMETER
Use of a differential voltage comparator as an alarm level control
Journal Article
·
Sat Mar 12 00:00:00 EST 1960
· Philips Technical Review (Netherlands)
·
OSTI ID:4811385
INSTRUMENTATION FOR A SUBCRITICAL HOMOGENEOUS SUSPENSION REACTOR. IIIB. THE MONITORING OF HIGH NEUTRON FLUX WITH THE AID OF AN ELECTROMETER
Journal Article
·
Sat Mar 12 00:00:00 EST 1960
· Philips Technical Review (Netherlands)
·
OSTI ID:4811385
Use of a differential voltage comparator as an alarm level control
Conference
·
Sat Jan 01 00:00:00 EST 1972
·
OSTI ID:4811385