Title: THE ACCURACY OF HEAT TRANSFER MEASUREMENTS IN A HIGH PRESSURE SLURRY LOOP

Technical Report ·
OSTI ID:4803105

The suitability of the high temperature (300 deg C) high pressure (1500 psia) thoria slurry circulating loop for obtaining reasonably accurate heat transfer measurements was considered. It is concluded that measurements of the heat transfer coefficient should be accurate to within plus or minus 25%. Other points of particular importance with respect to the pumping of thorta slurries are also discussed. These are the transition region in non-Newtonian flow, entrance effects, and the settling out of thoria particles. (arth)

Research Organization:
United Kingdom Atomic Energy Authority. Research Group. Atomic Energy Research Establishment, Harwell, Berks, England
NSA Number:
NSA-16-013201
OSTI ID:
4803105
Report Number(s):
AERE-R-3389
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-62
Country of Publication:
United Kingdom
Language:
English

Similar Records

HOMOGENEOUS REACTOR PROGRAM PROGRESS REPORT FOR PERIOD FROM AUGUST 1 TO NOVEMBER 30, 1960
Technical Report · Wed Mar 01 00:00:00 EST 1961 · OSTI ID:4803105

LARGE-SCALE SLURRY-CIRCULATION SYSTEM (300-SM)
Technical Report · Thu Dec 21 00:00:00 EST 1961 · OSTI ID:4803105

SLURRY MOCKUP RUN SM-10
Technical Report · Mon Mar 13 00:00:00 EST 1961 · OSTI ID:4803105