TEST OF P-102 PRIMARY SHIELD BOLTS. Report No. 419
Technical Report
·
OSTI ID:4801618
Torque tests were conducted on each type of bolt used in the P-102 primary shield components to obtain test data for use in the shield assembly. The torque value ranges needed to obtain the design preload for each bolt were determined. Actual assembly conditions were duplicated as to materials, nuts, and washers. A comparison was also made of thread lubrication methods including Molykoting with no excess remaining, dipping Molykote with the excess remaining on the bolt, and no lubrication at all. The type of bolts and test conditions were constant. The method of Molykote application has a very distinct effect on the torque versus tension characteristics of a bolt. (auth)
- Research Organization:
- General Electric Co. Aircraft Nuclear Propulsion Dept., Cincinnati
- DOE Contract Number:
- AT(11-1)-171
- NSA Number:
- NSA-16-014227
- OSTI ID:
- 4801618
- Report Number(s):
- DC-58-9-35
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-62
- Country of Publication:
- United States
- Language:
- English
Similar Records
Investigation of the effects of thrust and hardened washers on the installed tension of a roof bolt
RADIOACTIVE MATERIAL PACKAGING TORQUE REQUIREMENTS COMPLIANCE
MACHINING ELIMINATION THROUGH APPLICATION OF THREAD FORMING FASTENERS IN NET SHAPED CAST HOLES
Technical Report
·
Thu Jan 01 00:00:00 EST 1976
·
OSTI ID:4801618
RADIOACTIVE MATERIAL PACKAGING TORQUE REQUIREMENTS COMPLIANCE
Conference
·
Thu Mar 24 00:00:00 EDT 2011
·
OSTI ID:4801618
MACHINING ELIMINATION THROUGH APPLICATION OF THREAD FORMING FASTENERS IN NET SHAPED CAST HOLES
Technical Report
·
Wed May 02 00:00:00 EDT 2012
·
OSTI ID:4801618