Experimental study of the influence of non-proportional response of NaI(Tl) scintillation crystals upon the energy resolution for gamma rays
Abstract
The resolution of a summing Compton spectrometer ls accurately measured for several gamma ray energles. For the events detected, only one Compton scatterlng takes place in the first crystal. Thus for the part of the energy that is released ln the first crystal, the contrlbutlon to the line width arising otherwise from a varyng number of Compton electrons and non-proportlonal response of the scintillator is not present. Thls contrtbution ts evaluated by comparlng, for each energy, the resolutlon of the summing Compton spectrometer with the resolution expected if the total energy were shared by the two crystals in the same ratio, but multiple scatterlng were prcsent tn both of them. The results agree with theoretlcal expectattons. (auth)
- Authors:
- Publication Date:
- Research Org.:
- Nobel Inst. of Physics, Stockholm
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 4790733
- NSA Number:
- NSA-16-011890
- Resource Type:
- Journal Article
- Journal Name:
- Nuclear Instruments and Methods
- Additional Journal Information:
- Journal Volume: 14; Journal Issue: C; Other Information: Orig. Receipt Date: 31-DEC-62; Journal ID: ISSN 0029-554X
- Publisher:
- Elsevier
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
- Subject:
- ENGINEERING AND EQUIPMENT; COMPTON EFFECT; ENERGY LEVELS; GAMMA RADIATION; RESOLUTION; SCATTERING; SCINTILLATION COUNTERS; SODIUM IODIDES; SPECTROMETERS; THALLIUM
Citation Formats
Thieberger, P., Bonacalza, E. C. O., and Ryde, H. Experimental study of the influence of non-proportional response of NaI(Tl) scintillation crystals upon the energy resolution for gamma rays. Country unknown/Code not available: N. p., 1961.
Web. doi:10.1016/0029-554X(61)90078-7.
Thieberger, P., Bonacalza, E. C. O., & Ryde, H. Experimental study of the influence of non-proportional response of NaI(Tl) scintillation crystals upon the energy resolution for gamma rays. Country unknown/Code not available. https://doi.org/10.1016/0029-554X(61)90078-7
Thieberger, P., Bonacalza, E. C. O., and Ryde, H. Wed .
"Experimental study of the influence of non-proportional response of NaI(Tl) scintillation crystals upon the energy resolution for gamma rays". Country unknown/Code not available. https://doi.org/10.1016/0029-554X(61)90078-7.
@article{osti_4790733,
title = {Experimental study of the influence of non-proportional response of NaI(Tl) scintillation crystals upon the energy resolution for gamma rays},
author = {Thieberger, P. and Bonacalza, E. C. O. and Ryde, H.},
abstractNote = {The resolution of a summing Compton spectrometer ls accurately measured for several gamma ray energles. For the events detected, only one Compton scatterlng takes place in the first crystal. Thus for the part of the energy that is released ln the first crystal, the contrlbutlon to the line width arising otherwise from a varyng number of Compton electrons and non-proportlonal response of the scintillator is not present. Thls contrtbution ts evaluated by comparlng, for each energy, the resolutlon of the summing Compton spectrometer with the resolution expected if the total energy were shared by the two crystals in the same ratio, but multiple scatterlng were prcsent tn both of them. The results agree with theoretlcal expectattons. (auth)},
doi = {10.1016/0029-554X(61)90078-7},
url = {https://www.osti.gov/biblio/4790733},
journal = {Nuclear Instruments and Methods},
issn = {0029-554X},
number = C,
volume = 14,
place = {Country unknown/Code not available},
year = {1961},
month = {11}
}