A measuring system for the control of neutron flux in two decades and for the signalization of the preset flux level overshoot is described. The system consists of 3 identical measurement channeis operating on the principle two-out-of-three''. Component parts of the electronics equipment of the system, such as a d-c electrometer amplifier, trigger circuits of the power level to overcome signalization, and the circuits for signalization, of mismatch of the voltages at the outputs of 3 amplifiers, are described. Results of testing the main system parameters are given. (auth)

Authors:
Publication Date:
Research Org.:
Polish Academy of Sciences. Inst. of Nuclear Research, Warsaw
OSTI Identifier:
4718121
Report Number(s):
PAN-417/XII
NSA Number:
NSA-17-026900
Resource Type:
Technical Report
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-63
Country of Publication:
Country unknown/Code not available
Language:
English
Subject:
REACTOR TECHNOLOGY; AMPLIFIERS; ANNA; CIRCUITS; CONTROL SYSTEMS; CRITICAL ASSEMBLIES; ELECTRONIC EQUIPMENT; MEASURED VALUES; NEUTRON FLUX; POWER; REACTORS; RECORDING SYSTEMS; SIGNALS; TESTING

Citation Formats

Zelinski, T. A Linear d-c Channel "B" of the Control and Safety System for Zero Power Reactor ANNA; LINEINYI, TOKOVYI KANAL "V" SYSTEMY UPRAVLENIYA I ZASHCHITY REAKTORA NULEVOI MOSHCHNOSTI ANNA. Country unknown/Code not available: N. p., 1963. Web.
Zelinski, T. A Linear d-c Channel "B" of the Control and Safety System for Zero Power Reactor ANNA; LINEINYI, TOKOVYI KANAL "V" SYSTEMY UPRAVLENIYA I ZASHCHITY REAKTORA NULEVOI MOSHCHNOSTI ANNA. Country unknown/Code not available.
Zelinski, T. 1963. "A Linear d-c Channel "B" of the Control and Safety System for Zero Power Reactor ANNA; LINEINYI, TOKOVYI KANAL "V" SYSTEMY UPRAVLENIYA I ZASHCHITY REAKTORA NULEVOI MOSHCHNOSTI ANNA". Country unknown/Code not available.
@article{osti_4718121,
title = {A Linear d-c Channel "B" of the Control and Safety System for Zero Power Reactor ANNA; LINEINYI, TOKOVYI KANAL "V" SYSTEMY UPRAVLENIYA I ZASHCHITY REAKTORA NULEVOI MOSHCHNOSTI ANNA},
author = {Zelinski, T},
abstractNote = {A measuring system for the control of neutron flux in two decades and for the signalization of the preset flux level overshoot is described. The system consists of 3 identical measurement channeis operating on the principle two-out-of-three''. Component parts of the electronics equipment of the system, such as a d-c electrometer amplifier, trigger circuits of the power level to overcome signalization, and the circuits for signalization, of mismatch of the voltages at the outputs of 3 amplifiers, are described. Results of testing the main system parameters are given. (auth)},
doi = {},
url = {https://www.osti.gov/biblio/4718121}, journal = {},
number = ,
volume = ,
place = {Country unknown/Code not available},
year = {Fri Mar 01 00:00:00 EST 1963},
month = {Fri Mar 01 00:00:00 EST 1963}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share: