Title: Folded Compact Range Development and Coherent Change Detection Measurement Project

Abstract

A novel, folded compact range configuration has been developed at the Sandia National Laboratories compact range antenna and radar cross section measurement facility, operated by the Radar/Antenna Department 2343, as a means of performing indoor, environmentally-controlled, far-field simulations of synthetic aperture radar (SAR) coherent change detection (CCD) measurements. This report describes the development of the folded compact range configuration, as well as the initial set of coherent change detection measurements made with the system. These measurements have been highly successful, and have demonstrated the viability of the folded compact range concept in simulating SAR CCD measurements. It is felt that follow-on measurements have the potential of contributing significantly to the body of knowledge available to the scientific community involved in CCD image generation and processing, and that this tool will be a significant aid in the research and development of change detection methodologies.

Authors:
Publication Date:
Research Org.:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
45560
Report Number(s):
SAND-95-0389
ON: DE95009082; TRN: 95:003646
DOE Contract Number:
AC04-94AL85000
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: Mar 1995
Country of Publication:
United States
Language:
English
Subject:
44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; SYNTHETIC-APERTURE RADAR; RANGE FINDERS; TEST FACILITIES; ANTENNAS

Citation Formats

Sorensen, K.W. Folded Compact Range Development and Coherent Change Detection Measurement Project. United States: N. p., 1995. Web. doi:10.2172/45560.
Sorensen, K.W. Folded Compact Range Development and Coherent Change Detection Measurement Project. United States. doi:10.2172/45560.
Sorensen, K.W. 1995. "Folded Compact Range Development and Coherent Change Detection Measurement Project". United States. doi:10.2172/45560. https://www.osti.gov/servlets/purl/45560.
@article{osti_45560,
title = {Folded Compact Range Development and Coherent Change Detection Measurement Project},
author = {Sorensen, K.W.},
abstractNote = {A novel, folded compact range configuration has been developed at the Sandia National Laboratories compact range antenna and radar cross section measurement facility, operated by the Radar/Antenna Department 2343, as a means of performing indoor, environmentally-controlled, far-field simulations of synthetic aperture radar (SAR) coherent change detection (CCD) measurements. This report describes the development of the folded compact range configuration, as well as the initial set of coherent change detection measurements made with the system. These measurements have been highly successful, and have demonstrated the viability of the folded compact range concept in simulating SAR CCD measurements. It is felt that follow-on measurements have the potential of contributing significantly to the body of knowledge available to the scientific community involved in CCD image generation and processing, and that this tool will be a significant aid in the research and development of change detection methodologies.},
doi = {10.2172/45560},
journal = {},
number = ,
volume = ,
place = {United States},
year = 1995,
month = 3
}

Technical Report:

Save / Share:
  • A folded compact range configuration has been developed ant the Sandia National Laboratories` compact range antenna and radar-cross- section measurement facility as a means of performing indoor, environmentally-controlled, far-field simulations of synthetic aperture radar (SAR) measurements of distributed target samples (i.e. gravel, sand, etc.). The folded compact range configuration has previously been used to perform coherent-change-detection (CCD) measurements, which allow disturbances to distributed targets on the order of fractions of a wavelength to be detected. This report describes follow-on CCD measurements of other distributed target samples, and also investigates the sensitivity of the CCD measurement process to changes in themore » relative spatial location of the SAR sensor between observations of the target. Additionally, this report describes the theoretical and practical aspects of performing interferometric inverse-synthetic-aperture-radar (IFISAR) measurements in the folded compact range environment. IFISAR measurements provide resolution of the relative heights of targets with accuracies on the order of a wavelength. Several examples are given of digital height maps that have been generated from measurements performed at the folded compact range facility.« less
  • A folded compact range configuration has been developed at the Sandia National Laboratories` compact range antenna and radar cross section measurement facility as a means of performing indoor, environmentally controlled far-field simulations of synthetic aperture radar (SAR) measurements of distributed target samples (i.e. gravel, sand, etc.). In particular, the folded compact range configuration has been used to perform both highly sensitive coherent change detection (CCD) measurements and interferometric inverse synthetic aperture radar (IFSAR) measurements, which, in addition to the two-dimensional spatial resolution afforded by typical interferometric SAR (ISAR) processing, provides resolution of the relative height of targets with accuracies onmore » the order of a wavelength. This paper describes the development of the folded compact range, as well as the coherent change detection and interferometric measurements that have been made with the system. The measurement have been very successful, and have demonstrated not only the viability of the folded compact range concept in simulating SAR CCD and IFSAR measurements, but also its usefulness as a tool in the research and development of SAR CCD and IFSAR image generation and measurement methodologies.« less
  • In this paper, we derive a new optimal change metric to be used in synthetic aperture RADAR (SAR) coherent change detection (CCD). Previous CCD methods tend to produce false alarm states (showing change when there is none) in areas of the image that have a low clutter-to-noise power ratio (CNR). The new estimator does not suffer from this shortcoming. It is a surprisingly simple expression, easy to implement, and is optimal in the maximum-likelihood (ML) sense. The estimator produces very impressive results on the CCD collects that we have tested.
  • This report discusses an automatic target recognition (ATR) algorithm for synthetic aperture radar (SAR) imagery that is based on coherent change detection techniques. The algorithm relies on templates created from training data to identify targets. Objects are identified or rejected as targets by comparing their SAR signatures with templates using the same complex correlation scheme developed for coherent change detection. Preliminary results are presented in addition to future recommendations.
  • It is commonly observed that resolution plays a role in coherent change detection. Although this is the case, the relationship of the resolution in coherent change detection is not yet defined . In this document, we present an analytical method of evaluating this relationship using detection theory. Specifically we examine the effect of resolution on receiver operating characteristic curves for coherent change detection.