Operating experience feedback report: Assessment of spent fuel cooling. Volume 12
This report documents the results of an independent assessment by a team from the Office of Analysis and Evaluation of Operational Data of spent-fuel-pool (SFP) cooling in operating nuclear power plants. The team assessed the likelihood and consequences of an extended loss of SFP cooling and suggested corrective actions, based on their findings.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (United States). Div. of Safety Programs
- Sponsoring Organization:
- Nuclear Regulatory Commission, Washington, DC (United States)
- OSTI ID:
- 453755
- Report Number(s):
- NUREG-1275-Vol.12; ON: TI97004140; TRN: 97:006796