Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out
Abstract
Platform - Structural analyses were performed for design seismic, live and dead load combinations for the freestanding platform over the partial DST mock-up section. The platform is to be used for Robotic ultrasonic inspection of the tank wall. It is a free standing structure anchored to floor slab with Hilti Kwik bolts.
- Authors:
- Publication Date:
- Research Org.:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Org.:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- OSTI Identifier:
- 441121
- Report Number(s):
- WHC-SD-WM-ER-521
ON: DE97051469; TRN: 97:009752
- DOE Contract Number:
- AC06-96RL13200
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: 19 Dec 1995
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 05 NUCLEAR FUELS; HANFORD RESERVATION; RADIOACTIVE WASTE STORAGE; TANKS; INSPECTION; RADIOACTIVE WASTE FACILITIES; SEISMIC EFFECTS; EVALUATION; WALLS; DESIGN; ROBOTS; FINITE ELEMENT METHOD; HOISTS
Citation Formats
Hundal, T S. Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out. United States: N. p., 1995.
Web. doi:10.2172/441121.
Hundal, T S. Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out. United States. https://doi.org/10.2172/441121
Hundal, T S. 1995.
"Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out". United States. https://doi.org/10.2172/441121. https://www.osti.gov/servlets/purl/441121.
@article{osti_441121,
title = {Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out},
author = {Hundal, T S},
abstractNote = {Platform - Structural analyses were performed for design seismic, live and dead load combinations for the freestanding platform over the partial DST mock-up section. The platform is to be used for Robotic ultrasonic inspection of the tank wall. It is a free standing structure anchored to floor slab with Hilti Kwik bolts.},
doi = {10.2172/441121},
url = {https://www.osti.gov/biblio/441121},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Dec 19 00:00:00 EST 1995},
month = {Tue Dec 19 00:00:00 EST 1995}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.