Title: Multiwire proportional chamber development. Final report, 1 November 1970- -31 December 1972

Abstract

The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and / sup 55/Fe x-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC' s of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas. (auth)

Authors:
; ;
Publication Date:
Research Org.:
TRW Systems Group, Redondo Beach, Calif. (USA)
OSTI Identifier:
4388032
Report Number(s):
N-73-22210; NASA-CR-128899
NSA Number:
NSA-29-005234
DOE Contract Number:  
NAS9-11315
Resource Type:
Technical Report
Resource Relation:
Other Information: Orig. Receipt Date: 30-JUN-74
Country of Publication:
United States
Language:
English
Subject:
N46140* -Instrumentation-Radiation Detection Instruments- High Energy Physics Instrumentation; *COSMIC RAY DETECTION- MULTIWIRE PROPORTIONAL CHAMBERS; *MULTIWIRE PROPORTIONAL CHAMBERS- PERFORMANCE; GAIN; READOUT SYSTEMS; SPATIAL RESOLUTION

Citation Formats

Doolittle, R F, Pollvogt, U, and Eskovitz, A J. Multiwire proportional chamber development. Final report, 1 November 1970- -31 December 1972. United States: N. p., 1973. Web.
Doolittle, R F, Pollvogt, U, & Eskovitz, A J. Multiwire proportional chamber development. Final report, 1 November 1970- -31 December 1972. United States.
Doolittle, R F, Pollvogt, U, and Eskovitz, A J. Mon . "Multiwire proportional chamber development. Final report, 1 November 1970- -31 December 1972". United States.
@article{osti_4388032,
title = {Multiwire proportional chamber development. Final report, 1 November 1970- -31 December 1972},
author = {Doolittle, R F and Pollvogt, U and Eskovitz, A J},
abstractNote = {The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and / sup 55/Fe x-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC' s of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas. (auth)},
doi = {},
url = {https://www.osti.gov/biblio/4388032}, journal = {},
number = ,
volume = ,
place = {United States},
year = {1973},
month = {1}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.

Save / Share: