PRODUCTION TEST DATA SELF-ACTUATED REACTOR VESSEL RELIEF VALVES
Technical Report
·
OSTI ID:4337472
Production test data are presented for five selfactuated reactor relief valves. Four of these valves are installed in the pressurizer and pressure relief system. (W.L.H.)
- Research Organization:
- Westinghouse Electric Corp. Bettis Plant, Pittsburgh
- DOE Contract Number:
- AT-11-1-GEN-14
- NSA Number:
- NSA-12-011867
- OSTI ID:
- 4337472
- Report Number(s):
- WAPD-PWR-PMA-1504
- Resource Relation:
- Other Information: PWR Project. Orig. Receipt Date: 31-DEC-58
- Country of Publication: