Title: CONTINUATION OF HRT FUEL SOLUTION EVAPORATOR STUDY

Abstract

A third possible arrangement for the HRT fuel solution evaporator is shown. For this system, the evaporation is presumed to occur in 2 inclined 4-in. schedule 40 stainless steel steam-jacketed pipes supported below the inner dump tanks. In addition to its primary functions, the arrangement should also tend to keep the fuel solution in the dump tanks agitated. General specifications for the evaporator are listed. (W.L.H.)

Authors:
Publication Date:
Research Org.:
Oak Ridge National Lab., TN (US)
Sponsoring Org.:
US Atomic Energy Commission (AEC)
OSTI Identifier:
4332999
Report Number(s):
CF-54-6-31
NSA Number:
NSA-12-000831
DOE Contract Number:
W-7405-ENG-26
Resource Type:
Technical Report
Resource Relation:
Other Information: Decl. Apr. 2, 1957. Orig. Receipt Date: 31-DEC-58
Country of Publication:
United States
Language:
English
Subject:
ENGINEERING; EVAPORATION; FUEL SOLUTIONS; HOMOGENEOUS REACTORS; HRT; JACKETS; PIPES; RESEARCH REACTORS; STAINLESS STEELS; STEAM; STORAGE; VESSELS

Citation Formats

Segaser, C. L. CONTINUATION OF HRT FUEL SOLUTION EVAPORATOR STUDY. United States: N. p., 1954. Web. doi:10.2172/4332999.
Segaser, C. L. CONTINUATION OF HRT FUEL SOLUTION EVAPORATOR STUDY. United States. doi:10.2172/4332999.
Segaser, C. L. Tue . "CONTINUATION OF HRT FUEL SOLUTION EVAPORATOR STUDY". United States. doi:10.2172/4332999. https://www.osti.gov/servlets/purl/4332999.
@article{osti_4332999,
title = {CONTINUATION OF HRT FUEL SOLUTION EVAPORATOR STUDY},
author = {Segaser, C. L.},
abstractNote = {A third possible arrangement for the HRT fuel solution evaporator is shown. For this system, the evaporation is presumed to occur in 2 inclined 4-in. schedule 40 stainless steel steam-jacketed pipes supported below the inner dump tanks. In addition to its primary functions, the arrangement should also tend to keep the fuel solution in the dump tanks agitated. General specifications for the evaporator are listed. (W.L.H.)},
doi = {10.2172/4332999},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jun 01 00:00:00 EDT 1954},
month = {Tue Jun 01 00:00:00 EDT 1954}
}

Technical Report:

Save / Share: