Radiation induced currents in subminiature coaxial cables
Abstract
Subminiature coaxial csbles smaller than RG-58 were exposed to intense pulsed irradiation from a plasma focus device, and the currents induced on the center conductors were measured in a vacuum environment. The incident photons had energies mostly below 70 keV, and filters were used to vary the average hardness of the irradiation. The measured cable responses in units of Coulomb/ rad(Si)-cm were compared to values calculated on the basis of photoemission from metal surfaces and electron ranges in insulators. It was found that the currents induced on the center conductors were several times larger than predicted for an ideal coaxial geometry because of small gaps befween the dielectric surface and overlapping braid wires. For a given cable type, such as RG-174/U, large variations in cable responses were found according to each manufacturer's construction techniques. (auth)
- Authors:
- Publication Date:
- Research Org.:
- Aerospace Corp., El Segundo, CA
- OSTI Identifier:
- 4326219
- NSA Number:
- NSA-29-029572
- Resource Type:
- Conference
- Journal Name:
- IEEE (Inst. Elec. Electron. Eng.), Trans. Nucl. Sci., v. NS-20, no. 6, pp. 58-63
- Additional Journal Information:
- Conference: Annual conference on nuclear and space radiation effects, Logan, UT, 23 Jul 1973; Other Information: Orig. Receipt Date: 30-JUN-74
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
- Subject:
- N46300* -Instrumentation-Radiation Effects on Instrument Components, Instruments, or Electronic Systems; *COAXIAL CABLES- PHYSICAL RADIATION EFFECTS; ELECTRIC CURRENTS; PHOTOEMISSION; PULSED IRRADIATION; X RADIATION
Citation Formats
Bernstein, M J. Radiation induced currents in subminiature coaxial cables. Country unknown/Code not available: N. p., 1973.
Web.
Bernstein, M J. Radiation induced currents in subminiature coaxial cables. Country unknown/Code not available.
Bernstein, M J. 1973.
"Radiation induced currents in subminiature coaxial cables". Country unknown/Code not available.
@article{osti_4326219,
title = {Radiation induced currents in subminiature coaxial cables},
author = {Bernstein, M J},
abstractNote = {Subminiature coaxial csbles smaller than RG-58 were exposed to intense pulsed irradiation from a plasma focus device, and the currents induced on the center conductors were measured in a vacuum environment. The incident photons had energies mostly below 70 keV, and filters were used to vary the average hardness of the irradiation. The measured cable responses in units of Coulomb/ rad(Si)-cm were compared to values calculated on the basis of photoemission from metal surfaces and electron ranges in insulators. It was found that the currents induced on the center conductors were several times larger than predicted for an ideal coaxial geometry because of small gaps befween the dielectric surface and overlapping braid wires. For a given cable type, such as RG-174/U, large variations in cable responses were found according to each manufacturer's construction techniques. (auth)},
doi = {},
url = {https://www.osti.gov/biblio/4326219},
journal = {IEEE (Inst. Elec. Electron. Eng.), Trans. Nucl. Sci., v. NS-20, no. 6, pp. 58-63},
number = ,
volume = ,
place = {Country unknown/Code not available},
year = {Sat Dec 01 00:00:00 EST 1973},
month = {Sat Dec 01 00:00:00 EST 1973}
}