Title: Seismic analysis Livermore pool type reactor facility, Lawrence Livermore Laboratory

Technical Report ·
DOI:https://doi.org/10.2172/4325948· OSTI ID:4325948

A seismic evaluation of the Livermore Pool Type Reactor Facility located at the Lawrence Livermore Laboratory was conducted as part of a safety analysis being prepared for the Atomic Energy Commission. The safe shutdown earthquake for the Lawrence Livermore Laboratory site is defined, along with a brief discussion of its basis. The method of analysis and results are summarized for all critical components. It is concluded that the biological shield and containment building should withstand the safe shutdown earthquake without failures. The crane and heat exchanger could fail under worst-case loading conditions. Recommendations for modifying the crane and heat exchanger support are presented. (auth)

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
DOE Contract Number:
W-7405-ENG-48
NSA Number:
NSA-29-031360
OSTI ID:
4325948
Report Number(s):
UCRL-51507
Resource Relation:
Other Information: Orig. Receipt Date: 30-JUN-74
Country of Publication:
United States
Language:
English