EVALUATION OF PWR POWER OSCILLATION TEST AND RECOMMENDATIONS CONCERNING FUTURE OPERATIONAL AND TEST PROCEDURES
Technical Report
·
OSTI ID:4303232
The stability in the PWR core with respect to xenon oscillations was tested. An oscillation was deliberately established and followed through two cycles to determine if the plant response would exhibit convergent or divergent tendencies. A summary cf test procedures and results is given, as well as an evaluation of the test and recommendations for future teats. (J.R.D.)